2S350-35 SUW-35 1-1/4'' Inch SS304 Diaphragm Operated Solenoid Valve
2S350-35:
2S : 2 Position 2 Way Solenoid Valve With Stainless Steel Body
350 : The Orifice Size is 35mm
35 : The Port Size is G1 1/4''
The 2S350-35 solenoid valve body is made of 304# stainless steel, widely use in the Pneumatic,water and oil circuit system to connect through or turn off the serving system.
Technical Data of 2W & 2S Solenoid Valve:
2W Series | 2W025-08 | 2W040-10 | 2W160-15 | 2W200-20 | 2W250-25 | 2W350-35 | 2W400-40 | 2W500-50 |
2S Series | 2S025-08 | 2S040-10 | 2S160-15 | 2S200-20 | 2S250-25 | 2S350-35 | 2S400-40 | 2S500-50 |
Orifice Size | 2.5 | 4 | 15 | 20 | 25 | 35 | 40 | 50 |
Port Size | 1/4'' | 3/8'' | 1/2'' | 3/4'' | 1'' | 1-1/4'' | 1-1/2'' | 2'' |
Medium | Water, Air, Gas, Oil | |||||||
Action | Direct Acting | Semi-Direct Diaphragm Operated | ||||||
Function | 2 Way, Normally Closed | |||||||
Fluid Viscosity | 20 CST below | |||||||
Pressure Range | 0 to 1.0 Mpa | |||||||
Temp. Range | -5 to +85℃ |
Main dimension of 2W & 2S Series Solenoid Valves:
2S Series | 2W Series | A | B | C | D | E |
2S025-06 | 2W025-06 | 64.5 | 30 | 75 | 43 | 1/8'' |
2S025-08 | 2W025-08 | 64.5 | 30 | 75 | 43 | 1/4'' |
2S040-10 | 2W040-10 | 70.6 | 32 | 82.4 | 53 | 3/8'' |
2S160-10 | 2W160-10 | 101.5 | 57 | 117 | 69 | 3/8'' |
2S160-15 | 2W160-15 | 101.5 | 57 | 117 | 69 | 1/2'' |
2S200-20 | 2W200-20 | 107 | 57 | 123.5 | 73 | 3/4'' |
2S250-25 | 2W250-25 | 111.5 | 73.5 | 134.5 | 99 | 1'' |
2S350-35 | 2W350-35 | 142 | 95 | 172 | 123 | 1-1/4'' |
2S400-40 | 2W400-40 | 142 | 95 | 172 | 123 | 1-1/2'' |
2S500-50 | 2W500-50 | 172 | 123 | 209 | 168 | 2'' |
Applicability
The fluid in the line must match the medium calibrated in the selected solenoid valve series.
The temperature of the fluid must be less than the calibration temperature of the solenoid valve selected.
Solenoid valves allow liquid viscosity to be generally below 20 CST, greater than 20 CST should be noted.
Working pressure difference, the maximum pressure difference of the pipeline should be less than 0.04MPa, such as ZS, 2W, ZQDF, ZCM series and other direct-acting and step-by-step direct-acting type; when the minimum working pressure difference is greater than 0.04MPa, the pilot type can be used. Differential) Solenoid valve; the maximum working pressure difference should be less than the maximum calibration pressure of the solenoid valve; the general solenoid valve is one-way operation, so pay attention to whether there is a back pressure difference, if there is a check valve installed.
Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing
Welcome to your any question and inquiry!