| Application | ||||||
| Design | with leakage port | |||||
| Pressure rating | [bar] | 25 | ||||
| Tests / approvals | ||||||
| Pressure Equipment Directive | A possible classification to PED depends on the application and has to be carried out by the user / operator. | |||||
| Pressure Equipment Directive EAC | The adapter is intended for use in devices, machines and installations that do not fall under the categories of the technical rule TR CU 032/2013. | |||||
| Safety instructions | The compatibility between medium and product material has to be checked in all applications. | |||||
| Mechanical data | ||||||
| Weight [g] | 203 | |||||
| Materials (wetted parts) | stainless steel (1.4435 / 316L) ; surface characteristics : Ra<0,4 / Rz 4 | |||||
| Sensor connection | G 1 Aseptoflex Vario | |||||
| Process connection | Pipe fitting DN40 DIN 11864-1-A-BS | |||||
| Sealing | Gasket | |||||
| Hygienic equipment class to DIN 11866 | H4 | |||||
| Accessories | ||||||
| Items supplied | O-ring: 1 x 24 x 2, EPDM, FDA compliant, E30054 | |||||
| Accessories (optional) | O-ring: 1 x 24 x 2, FKM, FDA compliant, E30123 | |||||
| sealing ring: 1, PEEK, FDA compliant, E30124 | ||||||
| ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — E33302-00 — 26.11.2018 — | ||||||
| E33302 | ||||||