| Features | |||||||||||||
| Device type | Fiber-optic cables | ||||||||||||
| Functional principle | Proximity system | ||||||||||||
| Fiber-optic head design | Threaded sleeve | ||||||||||||
| Application | Standard | ||||||||||||
| Compatible fiber-optic amplifiers | WLL80, WLL180, GLL170(T) | ||||||||||||
| Sensing range max. | 710 mm (Sensing range of WLL80 at 8 ms) | ||||||||||||
| Minimal object diameter | 0.015 mm 1) | ||||||||||||
| Optical fiber head Angle of dispersion Integrated lens Compatibility tip adapters |
60° No Yes |
||||||||||||
| Optical fiber Compatibility with infrared light Optical fiber cable can be shortened Adapter end sleeves required |
No ✔ Yes |
||||||||||||
| Included with delivery | Mounting, 2 x M3 hexagon nut, 2 x washer, adapter sleeves, BF-WLL160-13 (1.3 mm) adapter sleeves, FC fiber cutter (5304141) |
||||||||||||
| 1) Minimum detectable object was determined at optimum measuring distance and optimum setting. Mechanics |
|||||||||||||
| Optical fiber head Light emission Thread diameter (housing) |
Axial M3 |
||||||||||||
| Optical fiber | |||||||||||||
| Fiber length | 2,000 mm | ||||||||||||
| Bending radius | 15 mm | ||||||||||||
| Dynamic flexibility (robotics) | No | ||||||||||||
| Outside diameter, optical fiber cable connection | 1.3 mm | ||||||||||||
| Fiber arrangement | Coaxial | ||||||||||||
| Core structure | S: Ø 0,5 mm, R: 9 x Ø 0,25 mm 1) Coaxial | ||||||||||||
| Material | |||||||||||||
| Optical fiber head | Stainless steel | ||||||||||||
| 1) | C = Coaxial, S = Sender, E = Receiver. | ||||||||||||
| 2 FIBER-OPTIC SENSORS | SICK Product data sheet | 2025-02-20 18:42:21 | |||||||||||||
| Subject to change without notice | |||||||||||||
| LL3-DT01 | Fiber-optic cables | |||||||||||||
| FIBERS | |||||||||||||
| Sheath Fibers |
Polyethylen (PE) Polymethylmethacrylat (PMMA) |
||||||||||||
| Weight | 20 g | ||||||||||||
| 1) C = Coaxial, S = Sender, E = Receiver. | |||||||||||||
| Ambient data | |||||||||||||
| Ambient operating temperature | –40 °C ... +70 °C | ||||||||||||
| Classifications | |||||||||||||
| ECLASS 5.0 | 27270905 | ||||||||||||
| ECLASS 5.1.4 | 27270905 | ||||||||||||
| ECLASS 6.0 | 27270905 | ||||||||||||
| ECLASS 6.2 | 27270905 | ||||||||||||
| ECLASS 7.0 | 27270905 | ||||||||||||
| ECLASS 8.0 | 27270905 | ||||||||||||
| ECLASS 8.1 | 27270905 | ||||||||||||
| ECLASS 9.0 | 27270905 | ||||||||||||
| ECLASS 10.0 | 27270905 | ||||||||||||
| ECLASS 11.0 | 27270905 | ||||||||||||
| ECLASS 12.0 | 27270905 | ||||||||||||
| ETIM 5.0 | EC002651 | ||||||||||||
| ETIM 6.0 | EC002651 | ||||||||||||
| ETIM 7.0 | EC002651 | ||||||||||||
| ETIM 8.0 | EC002651 | ||||||||||||
| UNSPSC 16.0901 | 39121528 | ||||||||||||
| Sensing ranges with WLL80 | |||||||||||||
| Operating mode 16 µs | 45 mm | ||||||||||||
| Operating mode 70 µs | 170 mm | ||||||||||||
| Operating mode 250 µs | 265 mm | ||||||||||||
| Operating mode 500 µs | 320 mm | ||||||||||||
| Operating mode 1 ms | 380 mm | ||||||||||||
| Operating mode 2 ms | 505 mm | ||||||||||||
| Operating mode 8 ms | 710 mm | ||||||||||||
| Sensing ranges with WLL180T | |||||||||||||
| Operating mode 16 µs | 40 mm | ||||||||||||
| Operating mode 70 µs | 130 mm | ||||||||||||
| Operating mode 250 µs | 200 mm | ||||||||||||
| Operating mode 2 ms | 350 mm | ||||||||||||
| Operating mode 8 ms | 600 mm | ||||||||||||
| Note | Sensing ranges related to fiber-optic sensors with type of light: visible red light | ||||||||||||