| With optical interface |  			No |  		
 		 			| Supporting protocol for TCP/IP |  			Yes |  		
 		 			| Supporting protocol for DeviceNet |  			No |  		
 		 			| Supporting protocol for other bus systems |  			No |  		
 		 			| Redundancy |  			No |  		
 		 			| IO link master |  			No |  		
 		 			| Supporting protocol for DeviceNet Safety |  			No |  		
 		 			| Supporting protocol for EtherNet/IP |  			Yes |  		
 		 			| Power dissipation |  			5.1 W |  		
 		 			| Thermal dissipation |  			17.4 BTU/h |  		
 		 			| Enclosure type rating |  			None (open-style) |  		
 		 			| Ethernet ports |  			1 Ethernet RJ45 Category 5 |  		
 		 			| CIP unconnected messages |  			128 + 128 (backplane + Ethernet) |  		
 		 			| Current draw |  			1 A @ 5.1V DC, 3 mA @ 24V DC |  		
 		 			| Ethernet cable |  			802.3 compliant shielded or unshielded twisted pair |  		
 		 			| Wiring category |  			2 - on Ethernet ports, 3 - on USB ports |  		
 		 			| Communication rate |  			10/100 Mbps |  		
 		 			| Connections supported, max |  			TCP: 128, CIP: 256 (CIP connections can be used for all explicit or all implicit applications. for example, a 1756-ENBT module has a total of 128 CIP connections that can be used for any combination of connections.) |  		
 		 			| Isolation voltage |  			30V (continuous), Basic Insulation Type, Ethernet to Backplane, USB to Backplane, and USB to Ethernet(Applies only to these modules/series: 1756-EN2T/D, 1756-EN2TR/C,1756-EN3TR/B), Type tested at 980V AC for 60 s |  		
 		 			| Supporting protocol for LON |  			No |  		
 		 			| Supporting protocol for ASI |  			No |  		
 		 			| Supporting protocol for PROFIBUS |  			No |  		
 		 			| Supporting protocol for CAN |  			No |  		
 		 			| Supporting protocol for INTERBUS |  			No |  		
 		 			| Supporting protocol for KNX |  			No |  		
 		 			| Supporting protocol for Modbus |  			No |  		
 		 			| Supporting protocol for Data-Highway |  			No |  		
 		 			| Supporting protocol for SUCONET |  			No |  		
 		 			| With potential separation |  			No |  		
 		 			| Supporting protocol for SERCOS |  			No |  		
 		 			| Supporting protocol for INTERBUS-Safety |  			No |  		
 		 			| Radio standard Bluetooth |  			No |  		
 		 			| Radio standard Wi-Fi 802.11 |  			No |  		
 		 			| Supporting protocol for AS-Interface Safety at Work |  			No |  		
 		 			| Supporting protocol for Foundation Fieldbus |  			No |  		
 		 			| Supporting protocol for PROFINET CBA |  			No |  		
 		 			| Supporting protocol for PROFINET IO |  			No |  		
 		 			| Supporting protocol for PROFIsafe |  			No |  		
 		 			| Supporting protocol for SafetyBUS p |  			No |  		
 		 			| Radio standard GPRS |  			No |  		
 		 			| Radio standard GSM |  			No |  		
 		 			| Radio standard UMTS |  			No |  		
 		 			| Slot width |  			1 |  		
 		 			| ATEX temp code |  			T4 |