| Model |  			LR-ZB100N |  		
 		 			| Type |  			Distance based laser sensor |  		
 		 			| Appearance |  			Rectangular |  		
 		 			| Output |  			NPN |  		
 		 			| Cable connection |  			2 m cable |  		
 		 			| Detectable distance |  			35 to 100 mm 1.38" to 3.94" (650 to 0)*1 |  		
 		 			| Standard detectable deviation |  			35 to 50 mm 1.38" to 1.97": 1.5 mm 0.06"  			50 to 100 mm 1.97" to 3.94": 3 mm 0.12" |  		
 		 			| Display resolution |  			2 (0.2 mm 0.008") |  		
 		 			| Spot size |  			Approx. 2 × 1 mm 0.08" × 0.04" at 100 mm 3.94" |  		
 		 			| Response time |  			1.5 ms / 10 ms / 50 ms selectable |  		
 		 			| Light source |  			Type |  			Red laser (660 nm) |  		
 		 			| Laser class |  			Class 1 laser product  			(IEC60825-1, FDA (CDRH) Part1040.10*2) |  		
 		 			| Function |  			Indicator |  			3-digit 7-segment display (red),  			output indicator (yellow),  			DATUM indicator (orange),  			1 spot indicator (green) |  		
 		 			| Timer |  			OFF/ON delay/OFF delay/One-shot |  		
 		 			| Specifications |  			Power voltage |  			10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS |  		
 		 			| Power consumption |  			450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V) |  		
 		 			| Control output |  			NPN Open collector,  			Applied voltage 30 VDC or less, Control current 100 mA or less,  			Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mA |  		
 		 			| Protection circuit |  			Protection against reverse power connection, output overcurrent, output surge, reverse output connection |  		
 		 			| Output operation |  			Light-ON / Dark-ON selectable |  		
 		 			| External input |  			Input time calibration: 35 ms or more ON, 35 ms or more OFF  			Laser emission stop: 2 ms or more ON, 20 ms or more OFF  			Short-circuit current NPN: 1 mA or less/PNP: 2 mA or less |  		
 		 			| Environmental resistance |  			Enclosure rating |  			IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*3, Diversey*3 |  		
 		 			| Insulation resistance |  			20 MΩ or more (500 VDC) |  		
 		 			| Ambient light |  			Incandescent lamp: 4,000 lux or less  			Sunlight: 8,000 lux or less*4 |  		
 		 			| Ambient temperature |  			-10 to +50 °C 14 to 122 °F (No freezing) |  		
 		 			| Storage temperature |  			-25 to +75 °C -13 to 167 °F (No freezing) |  		
 		 			| Relative humidity |  			35 to 85 % RH (No condensation) |  		
 		 			| Withstand voltage |  			1,000 VAC, 50/60 Hz, 1 min |  		
 		 			| Vibration resistance |  			10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |  		
 		 			| Shock resistance |  			1,000 m/s2, 6 times in each of the X, Y, and Z directions |  		
 		 			| Material |  			Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating,  			Packing/Connector ring: FKM |  		
 		 			| Accompanying items |  			Instruction Manual,  			Certification/Identification label (FDA) |  		
 		 			| Weight |  			Approx. 110 g (Including cable) |