Specifications
Brand Name :
Daruifuno
Model Number :
ASP300-NYD05
Certification :
CE
Place of Origin :
China
MOQ :
1
Payment Terms :
T/T, Western Union, MoneyGram
Supply Ability :
10000 Sets per Month
Delivery Time :
5-25 days
Packaging Details :
Carton
Price :
USD OR RMB
Product Name :
PH sensor
Model :
ASP300-NYD05
PH :
0~14pH 0.01pH
Materials in contact with liquid :
ABS+Glass+g
Working Temperature :
0.0~60.0℃
Working Pressure: :
0~2Bar
Reference reference electrode :
Ag/AgCl
Reference System :
Double salt bridge
Temperature compensation :
NTC10K
Cleaning :
Cleaning interface(Optional)
Description

Industry Online PH Probe With NTC10K Temp. Compensation For Industrial Water

There are three kinds of shells: Glass material is corrosion-resistant, ABS’s structure is firm, PPS shell is resistant to high temperature and corrosion; Low noise lead with customizable length within 60 meters.

The ring-shaped ceramic hole and porous membrane have the advantages of fast response, not easy to be blocked, and easy to clean; The ceramic hole sand core has the characteristics of smooth response, no potential drift, and good stability;

Specification:

Modle
ASP300-NYD05
PH Range
0~14pH 0.01pH
Shaft Material
ABS
Working TEMP
0~60℃
Reference System
double salt bridge
Reference Electrode
Ag/AgCl
Electrolyte
Solid Gel
Working Pressure
0~2Bar
Operating Temperature
0~60℃
Working Pressure
0~2Bar
Temperature Unit
NTC10K
Membrane
Porous
Glass Head

Transparent low impedance

Dimension
Diameter: 35mm Length: 260 mm ( include the cleaning cover)
Thread Size
1 inch NTP(both ends)
Lead Wire
Standard 5m
Ground
--
Cleaning
A protective cover with its own cleaning interface(Optional)
Application
Industrial water

Please click the pH sensor user manual here:

PH sensor User Manual.pdf

Brief introduction:
◆ The electrode is equipped with a protective cover with its own cleaning interface, and the user can quickly access the automatic cleaning system;


◆ The electrode is divided into 3 basic models according to the packaging method of the temperature unit;


◆ The indicator electrode adopts a low-impedance hemispherical glass head, which has high strength and is not easily broken;


◆ The reference adopts a large-area annular porous membrane, which has fast penetration speed, fast response, not easy to block, and easy to clean;


◆ The reference system is designed with double salt bridge, the reference electrode is Ag/AgCl, filled with KCL solid gel.

Industry Online PH Probe With  NTC10K Temp. Compensation For Industrial Water

Aplication: Water treatment monitoring

Drinking water,surface water,water quality analyze,ground water,ect.

Industrial process monitoring and dosing control

Chemical,petroleum,paper,food and medicine,PCB manufacturing,etc.

FAQ

1. What is themeasurement principle of this pH electrode?
A:
The pH value potentiometric method uses the potential difference of glass electrodes for pH measurement.


2. How is this glass pH electrode composed?
A:
The pH electrode is usually composed of an indicator electrode and a reference electrode.

3. How to judge the pH of the solution?
A:
If the internal hydrogen ion concentration of the pH glass bulb is lower than the outside, the measured solution is recorded as acidic and the pH value is lower than 7; if the two are the same, the solution is neutral and the pH value is equal to 7; if the internal hydrogen ion concentration is higher than externally, the measured solution is alkaline and the pH value is higher than

4. What is the wire length of the pH electrode?
A:
The lead wire of this electrode is 5m by default, other lengths need to be customized, contact our customer service, the price will vary with the change of length.


5. Are you trading company or manufacturer ?
A: We are factory.


6: How long is your delivery time?
A: Generally it is 3-5 working days if the goods are in stock. or it is 5-10 working days if the goods are not in stock, it is according to quantity.

7. How often must the pH sensor be calibrated?
A: Depends on the type of sample:
Dirty samples and non-aqueous samples require more frequent calibration.
Depends on the required accuracy:
For very accurate measurements, at least daily calibration is required.
Depends on the quality of the electrode:
Old electrodes require more frequent calibration.

Send your message to this supplier
Send Now

Industry Online PH Probe With NTC10K Temp. Compensation For Industrial Water

Ask Latest Price
Watch Video
Brand Name :
Daruifuno
Model Number :
ASP300-NYD05
Certification :
CE
Place of Origin :
China
MOQ :
1
Payment Terms :
T/T, Western Union, MoneyGram
Contact Supplier
video
Industry Online PH Probe With  NTC10K Temp. Compensation For Industrial Water
Industry Online PH Probe With  NTC10K Temp. Compensation For Industrial Water
Industry Online PH Probe With  NTC10K Temp. Compensation For Industrial Water
Industry Online PH Probe With  NTC10K Temp. Compensation For Industrial Water

Suzhou Delfino Environmental Technology Co., Ltd.

Verified Supplier
6 Years
jiangsu, suzhou
Since 2015
Business Type :
Manufacturer, Exporter, Seller
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement