Technical Features | ||||||
Charging capacity | Type2 & GB/T --7kW/11kW/22kW | |||||
Charging capacity | Type1 & Tesla --7kW/9.6kW/11.5kW | |||||
Input/Output power-7kw | 220-240VAC-32A-1phase Type2 & GB/T | |||||
Input/Output power-11kw | 380-400VAC-16A-3phase Type2 & GB/T | |||||
Input/Output power-22kw | 380-400VAC-32A-3phase Type2 & GB/T | |||||
Input/Output power-7kw | 240VAC-30A-1phase Type1 & Tesla | |||||
Input/Output power-9.6kw | 240VAC-40A-1phase Type1 & Tesla | |||||
Input/Output power-11.5kw | 240VAC-50A-1phase Type1 & Tesla | |||||
Input/Output frenquency | 50/60Hz | |||||
RCD | 30Ma RCD Type A and DC 6Ma RCD function | |||||
Standby power | <3W | |||||
Measuring accuracy | 1% | |||||
Control | Plug and play | |||||
User interface | RFID/ WIFI / APP optional ( contact customer service first ) | |||||
Certificate / Compliance | CE / FCC / RoHS | |||||
Charging Interface | Type2 /Type1/GBT/Tesla | |||||
Cable | 5M | |||||
OCPP | 1.6/2.0 optional ( contact customer service first ) | |||||
Physical properties | ||||||
Warranty | 2 years | |||||
Protection | IP55 | |||||
Special Protection | Over current protection, Residual current protection, Ground protection, Surge protection, Over/Under voltage protection, Over/Under frequency protection, Over/Under temperature protection | |||||
Installation | Wall-mount/Pole-mount | |||||
Cooling | Natural cooling | |||||
Operating temperature | -30℃ to +55℃ | |||||
Humidity | Max.95%(non-regulating) | |||||
Package Dimensions | 530*430*220(L*W*H)mm | |||||
Net Weight | 6.5Kg | |||||
Gross Weight | 8Kg | |||||