Specifications
Brand Name :
PHiliph
Model Number :
GSI 600-23100-16 XE-50A
MOQ :
1pcs
Payment Terms :
Full before shipment
Delivery Time :
3-5 working days
Packaging Details :
Carton
Product Name :
Printer Recorder GSI 600-23100-16 XE-50A For PHiliph MP20 MP30 Patient Monitor
Brand :
PHiliph
Part No :
GSI 600-23100-16 XE-50A
Application :
PHiliph MP20 MP30 Patient Monitor
MOQ :
One piece
Warranty :
90 days
Condition :
Work in Good
Delivery Method :
DHL,UPS ,Fedex
Description

Printer Recorder GSI 600-23100-16 XE-50A For PHiliphh MP20 MP30 Patient Monitor

PHiliphh MP20 MP30 Patient Monitor Printer Recorder GSI 600-23100-16 XE-50A

About PHiliphh MP20 MP30 Patient Monitor Printer Recorder GSI 600-23100-16 XE-50A

PHiliphh MP20 and MP30 patient monitors are medical devices used to monitor vital signs and other patient data. Both models include a printer-recorder feature that makes it easy to record patient information.

Printer recorders allow medical professionals to obtain hard copies of patient data, including vital signs such as blood pressure, heart rate, oxygen saturation, and respiratory rate. This important feature allows medical staff to easily view and share patient information.

Printer Troubleshooting

Symptoms Cause of Failure Failure Isolation and Remedy
Prompt message “Print job could not be queued” is issued. No print device is found. Printer is disabled in the Setup Printers menu Paper size of printer does not match paper size of report Enable the correct printer in the Setup Printers menu Change paper size of the printer in the Setup Printers menu or change paper size of the report in the Setup Reports menu.
Status message “Print device Local 1 (Local 2) unavailable” is issued. Pr Printer not switched on Printer paper tray empty Cabling not connected correctly PS/2 or USB I/O board defective Switch on printer power fill printer paper tray Check cabling replace I/O board
Status message “Print device Remote 1 (Remote 2, Remote 3) unavailable” is issued. Printer job is stalled Print error on PHiliphh Information Center Network Connection to PHiliphh Information Center not functioning Print a test report on the PHiliphh Information center. If this fails, refer to PHiliphh Information Center documentation Check that the network connection between the monitor and the PHiliphh Information Center is working
Status message “Printing on device Remote 1... (Remote 2, Remote 3)” is issued but no report is printed Print queue on PHiliphh Information Center is full. Reasons for this may be: - Printer is not switched on - Printer paper tray is empty

Switch on printer power Fill printer paper tray

Configure the paper size according to the inserted print media Configure the printer resolution according to the printer capabilities Configure the printer color support to “Off” Check specifications

Printouts are not as expected Printer paper size is not correctly configured Printer resolution is not correctly configured Printer color support is configured to “On” although the printer does not support color Printer not compatible

GSI 600-23100-16 XE-50A Printer Recorder For PHiliph MP20 MP30 Patient Monitor

Thank you so much for your attention .If you're interested in Printer Recorder GSI 600-23100-16 XE-50A For PHiliphh MP20 MP30 Patient Monitor ,feel free to contact us .Thank you .

Send your message to this supplier
Send Now

GSI 600-23100-16 XE-50A Printer Recorder For PHiliph MP20 MP30 Patient Monitor

Ask Latest Price
Brand Name :
PHiliph
Model Number :
GSI 600-23100-16 XE-50A
MOQ :
1pcs
Payment Terms :
Full before shipment
Delivery Time :
3-5 working days
Packaging Details :
Carton
Contact Supplier
GSI 600-23100-16 XE-50A Printer Recorder For PHiliph MP20 MP30 Patient Monitor
GSI 600-23100-16 XE-50A Printer Recorder For PHiliph MP20 MP30 Patient Monitor
GSI 600-23100-16 XE-50A Printer Recorder For PHiliph MP20 MP30 Patient Monitor

China World Technology Medical Equipment Service Group

Verified Supplier
5 Years
guangdong, guangzhou
Since 2015
Business Type :
Manufacturer, Distributor/Wholesaler, Agent, Importer, Exporter, Trading Company, Seller
Employee Number :
20~50
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement