P/N M3535-62301 PHiliphh MRX Defibrillator Spare Parts NBP Module

NBP Module

The NBP module performs the following functions:

• Inflate and deflate the NIBP cuff.

• Measure the pressure in the cuff.

• Detects the pressure waveform and extracts the systolic and diastolic values from the waveform.

• Calculates mean pressure based on waveform, systolic and diastolic data

The NBP and CO2 modules are mounted on the tray. To replace any module, you must remove the tray and then replace each module.

Preparation

1. Open and remove the housing.

2. Check the position of the rear housing

3. Remove the therapy capacitor.

4. Remove the NBP and CO2 module tray

P/N M3535-62301 PHiliph MRX Defibrillator Spare Parts NBP Module

Move

Remove the NBP module and screen

A. Loosen and remove the four T-10 screws.

B. Lift the NBP module and shield out of the module tray.

Replacement

1. Replace the NBP module and screen.

Place the NBP module and screen on the module tray.

2. Replace the screw and tighten.

3. Replace the NBP and CO2 module tray.

4. Replace the therapy capacitor

5. Turn off the house.

NBP Monitoring Problems

Symptom Possible Causes Suggested Solution
NBP Equip Malfunction NBP hardware malfunction Replace NBP module
NBP Calibration Overdue The NBP module should be calibrated once a year or every 10,000 cycles Calibrate the NBP module
NBP Measurement Failed A measurement value could not be obtained. Check accuracy
NBP Service Required The NBP module has reached its end of life, defined as 50,000 cycles. Replace NBP module
Measurement cycle doesn’t start.
  • Problem with internal tubing connections
  • Failure of front panel button.
  • NBP module failure
  • Processor PCA failure.
  • Check internal tubing. Reconnect/replace as needed.
  • Run Controls test in Service Mode to confirm. Replace Display assembly if needed.
  • Replace NBP module
  • Replace Processor PCA
Pump operates, cuff inflates normally, but cuff will not deflate. NBP module failure Replace NBP module.
Reading inaccurate
  • NBP module needs calibration
  • NBP module failure
  • Check accuracy
  • Replace NBP module

NBP Check

  • Setup
  • Check the status displays
  • Test the accuracy
  • Test for leaks
  • Test the linearity
  • Calibrate the NBP Measurement
  • Run an Operational Check

Each procedure assumes that the monitor/defibrillator, pressure gauge, and inflation chamber are still configured as they were when the previous test was completed.

If all results are as indicated, the device passes this section of the test. Press the [Main Service] softkey to return to the service mode main menu.

In the event of a malfunction, start troubleshooting and repair the device as necessary.

If you're interested in P/N M3535-62301 PHiliphh MRX Defibrillator Spare Parts NBP Module ,feel free to contact us .Thank you .

Send your message to this supplier
Send Now

P/N M3535-62301 PHiliph MRX Defibrillator Spare Parts NBP Module

Ask Latest Price
Brand Name :
PHiliph
Model Number :
M3535-62301
MOQ :
1pcs
Payment Terms :
T/T(wire transfer), Western Union, Paypal
Delivery Time :
3-5 working days
Packaging Details :
Carton
Contact Supplier
P/N M3535-62301 PHiliph MRX Defibrillator Spare Parts NBP Module
P/N M3535-62301 PHiliph MRX Defibrillator Spare Parts NBP Module
P/N M3535-62301 PHiliph MRX Defibrillator Spare Parts NBP Module
P/N M3535-62301 PHiliph MRX Defibrillator Spare Parts NBP Module

China World Technology Medical Equipment Service Group

Verified Supplier
5 Years
guangdong, guangzhou
Since 2015
Business Type :
Manufacturer, Distributor/Wholesaler, Agent, Importer, Exporter, Trading Company, Seller
Employee Number :
20~50
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement