Drager O2 Sensor REF 6850645 New and Original Medical Equipment with Fast Shipment
Guangzhou YIGU Medical Equipment Service Co.,Ltd
Company Strengths
- 1. We are able to provide all kinds of medical equipment parts, hospital devices, patient facility accessories and complete machines.
- 2. We are able to offer maintenance service by professional medical equipment engineer with over 10 years specialized skills.
- 3. We have been solved more than 90% of MP series medical patient monitor module malfunctions (including software and hardware), and repair M3001A modules more than 400 pcs every year.
- 4. We deal with all medical patient monitors’ main brands including: GE, , SPACELABS, SIEMENS, NIHON KOHDEN, MINDRAY, Endoscopy, TYCO, NONIN etc.
- 5.Our principle: integrity and pragmatic, efficient and innovative, fearless and careful, professional service.
1. Maintenance Services: ECG monitor, Defibrillator, Oximeter, Electrocardiograph, Fetal monitor
2. Sell and Replace: Mainboard, Circuit board, Power strip/ panel, Battery, SP O2 and ECG module, Parameter module, Display screen, Touch screen, Encoder, Keyboard plate, Sensor, Probe, Cable etc.
3. Service Brands: GE, , SPACELABS, SIEMENS, MINDRAY, NIHON KOHDEN, Endoscopy, TYCO, NONIN, TOSHIBA, MEDISON, BIOSOUND, HITACHI, HP, ATL, ALOKA etc.
Details introduction
- (1) Repair and replace EGG, Defibrillator, Electrocardiogram Monitoring , Fetal Monitor Oximeter and parts.
- (2) Detect and judge Circuit Board, Power Stripe/Panel, ECG PCB, SPO2 PCB, NIBP PCB, Display Screen , Touch Screen, Keyboard Plate, Parameter PCB, Rotary Knob etc.
- (3) Sell and replace all kinds of Power Supply, ECG PCB, SPO2 PCB,NIBP PCB, Display Screen, Touch Screen , Keyboard Plate, Parameter PCB, Rotary Knob.
- (4) Monitor/ Electrocardiograph for leasing, maintenance, guarantee repairing and replacing.
| - Agilent M1460A Sensor, Intellivue G5-M109A, Intellivue MX40,
- M1205A , M1001A, M1012A, M1034A, M3001A, M3012A,M3014A, M3015A,M3046A,
- MP2 X2,MP20,MP30, MP40, MP5, MP50 , MP60, MP70, MP80, MP90,
- V24E(M1204A), VM4, VM6, VM8,VS2+, VS3
|
GE | - B20, B20i, B30, B40, B40i, B650, B850,
- DASH1800, DASH2000, DASH2500, DASH3000, DASH5000, Cardiocap 5,
- Datex-Ohmeda S3/S4/S5, GE DT-4500, Marquette EAGLE 4000,
- PRO1000, PRO300,
- SOLAR8000, SOLAR8000i, SOLAR8000M,
- V100, SAM Smart, SAM80
|
Nihon Kohden | - BSM-2301A, BSM-2301K, BSM-2304A, BSM-2351A, BSM-2351C, BSM-4104A, BSM-5106A
- GF-210R, MU-631KA, WEP-4204K, WEP-4208A
|
Mindray | - IMEC8, IMEC10, IMEC12,
- IPM8, IPM10, IPM12, IPM9800, MEC-1000, MEC-1200, MEC-200, MPM,
- PANORAMA, PM6000, PM1000, PM8000, PM8000E, PM9000, PM9000E,
- T1, T5, T6, T8, VS-800
|
Spacelabs | - 90309, 90369, 90518,91369, 91370, 91387, 91388, 91393, 91496, 91518,
- elance93300,mCare300
|
Siemens | - SC6002,SC6000,SC7000,SC6002 XL
|
Tyco | |
Common Faults Repair
- 1. Unbootable/ Unable to boot up. 2. The module ( M3001A ) can’t detect blood pressure.
- 3. The module can’t be connected. 4. Automatically disconnect.
- 5. The sphygmomanometer has a leak. 6. NIBP equipment failure.
- 7. Unable to contact. 8. Error reporting MMS disconnected.
- 9. False alarm MMS pull out. 10. Can’t load out.
- 11. ECG malfunctions. 12. ECG equipment out of order.
- 13. Software upgrades. 14. NIBP fails to inflate.
- 15. IBP equipment faults. 16. M3012A module can’t be detected.
- 17. Automatically restart. 18. The encoder can’t work.
- 19. Blue screen appears after startup. 20. No ECG signal.
- 21. Unable to enter the select menu. 22. Alarm occurs when starting up, and the failure light is on.
- 23. Report CO2 plugging. 24. MMSL developing module faults.
- 25. M3015A / M3001A module faults. 26. No power display light.
- 27. NBP equipment faults. 28. ECG and oximeter equipment faults.
- 29. LCD lamp aging. 30. Inflated blood pressure does not indicate a number.
- 31. The key plate is out of order. 32. Encoder failure.
- 33. Can’t inflate. 34. NIBP equipment faults.
- 35. SP O2 and ECG equipment fault. 36. Unable to charge.
- 37. The touch screen can’t work. 38. The screen shows double image.
- 39. Error code 1000. Error code 20004. 40. No alarm sounds.
