KCO-1608D Fiber optic splitter closure box is new design to sastify new FTTH demand. It can install 1 pc of 1*8 PLC splitter. Make by high quality PC material, life time is longer.
| Model | KCO-GJS22 |
| Dimension | 290*190*110mm |
| Cable diameter | Φ7-φ18mm |
| Cable port |
4pcs round ports 16pcs 2*3mm drop cable ports |
| Max. Split ratio | 2pcs 1x8 mini splitter |
| Max. Splice tray | 1pc |
| Max. Fusion splice |
24 cores |
| Main body | 1 set |
| L=400mm bare fiber buffer tube | 2 pcs |
| Hoop / clamp | 2 pcs |
| 3x100 nylon tie | 26 pcs |
| Heat shrinkable tube L=60mm | 2-72 pcs (configuration on demand) |
| User manual | 1pc |
| Characteristics | Value/Performance | Methods and Conditions |
|---|---|---|
| Mechanical | ||
| Air Tightness | No air bubble seen | Put closure under water for 15min with closure's internal air pressure set at 100kPa±5kPa. |
| Remains100kPa±5kPa | Measure the internal pressure 24 hours later | |
| Air Tightness after re-installation | No air bubble seen and pressure remains unchanged | Do re-entry and re-installation 3 times and repeat above Air Tightness Tests. |
| Axial Pulling | Pressure remains unchanged | Pulling force: 1000N Time: 1min Internal air pressure: 60kPa±5kPa |
| Compression | Pressure remains unchanged | Applied pressure: 2000N/100mm Time: 1min Internal air pressure: 60kPa±5kPa |
| Impact | Pressure remains unchanged | Impact energy: 16N.m No. of impacts: 3 Internal air pressure: 60±5kPa |
| Bending | Pressure remains unchanged | Bending angle±45°(in two opposite directions) Tension: 150N No. of bending: 10 Internal air pressure: 60kPa±5kPa |
| Twisting | Pressure remains unchanged | Twisting angle: ±90° Torque: 50N No. of twisting: 10 Internal air pressure: 60kPa±5kPa |
| Thermal | ||
| Temperature Cycling | Pressure drop ≤5kPa | Cycling range: -40 ~ +60°C Cycling time: 2hrs at -40°C, then 2hrs at +60°C No. of cycling: 3 Internal air pressure: 60kPa±5kPa |
| Electrical | ||
| Insulation | Resistance between metal parts:2.0x105MΩ |
Soak closure into water in 1.5m-depth for 24hrs, and measure the insulation resistance after taking it out of water. |
| Resistance between each metal part and ground:2.0x105MΩ | ||
| High Voltage | No voltage break-downs and sparks | Soak closure into water in 1.5m-depth for 24hrs, then apply 15kV DC to the metal parts inside |