Single Facer Medium Alignment
System Features
- The position of the tile paper is detected by the main electric eye (grating electric eye) installed in the core paper part of the single-sided movement.
- The bottom paper is guided by the correction frame installed above the bottom paper preheating cylinder, ensuring the bottom paper aligns with the center or edge of the tile paper before entering the single-sided machine.
- The single-faced alignment ensures that corrugated paper and bottom paper achieve precise center or edge alignment during the laminating process.
Detection Technology: Original imported German OSRAM LED detection electric eye
Detection Accuracy: +/-1mm