4H2-40000 Electrochemical Hydrogen Gas Sensor For Environmental & Equipment Control
Product Applications:
The 4H2-40000 gas sensor is an electrochemical hydrogen (H₂) sensor designed for:
- Industrial Safety Monitoring
- Detecting hydrogen leaks in petrochemical plants, refineries, and metallurgical facilities.
- Monitoring H₂ concentrations in coal mines and fire - fighting scenarios to prevent explosions.
- Environmental & Equipment Control
- Used in portable or fixed detection devices for hydrogen - related environmental monitoring.
- Suitable for hydrogen - powered vehicle systems, fuel cell stations, and laboratory gas safety checks.
- Wide - Range Sensing
- Ideal for applications requiring high - range H₂ detection (0–40,000 ppm), including industrial process control and gas storage areas.
Product Features:
- Ultra - Wide Measurement Range
- 0–40,000 ppm (0–100% LEL), enabling detection from low - level leaks to high - concentration environments.
- High Sensitivity & Resolution
- Sensitivity: 0.007 ± 0.002 μA/ppm; resolution: 80 ppm, ensuring precise H₂ concentration monitoring.
- Rapid Response
- Response time (T90): ≤60 seconds, allowing immediate alerts for sudden H₂ leaks.
- Stable Performance
- Baseline drift: Equivalent to 0–20 ppm; long - term output drift: <2% signal/month, ensuring consistent reliability.
- Robust Environmental Adaptability
- Operating temperature: -20°C–50°C; humidity: 15%–90% rh (non - condensing); pressure: 90–110 kPa.
- Three - Electrode Design
- Enhances anti - interference capability and measurement accuracy in complex gas environments.
- Long Service Life
- Expected lifespan: 2 years in clean air; storage life: 6 months (original packaging), reducing replacement costs.
- Compact & Versatile
- 4 - series size (≈5g), compatible with both portable and fixed - mounted detection equipment.
Key Technical Advantages:
- Low Cross - Sensitivity
- Minimal interference from gases like H₂S, SO₂, and Cl₂ (refer to cross - sensitivity data for details).
- Zero Bias Voltage
- Requires 0 mV bias voltage, simplifying circuit design for sensor integration.
- Intrinsic Safety
- Safe for use in hazardous areas with explosive gas mixtures (consult safety certifications for compliance).
Product Code | 2112b0644400 |
Measuring Range | 0 - 40,000 ppm H2 (0 - 100% LEL value) |
Operating Principle | Three - electrode electrochemical |
Gas Sensitivity | 7 ± 2 nA/ppm |
Response Time (T90) | ≤ 60 s (typical 35 s) |
Repeatability | < ± 2% signal |
Linearity | Linear |
Long - term Output Drift | < 2% signal/month |
Resolution | 70 ppm |
Recommended Load | 5 - 35 Ω |
Bias Voltage | 0 mV |
Operating Temperature Range | - 30℃ - 50℃ |
Operating Humidity | 15% rh - 90% rh (non - condensing) |
Operating Pressure Range | 800 - 1200 mbar |
Recommended Storage Temperature | 0℃ - + 20℃ (in sealed package) |
Expected Operating Life | 24 months in air |
Storage Life | 6 months in original package |
Standard Warranty | 18 months from the date of delivery |
Cross - sensitivity (Carbon Monoxide 50 ppm) | 170 ppm H2 equivalent |