Specifications
Model Number :
AO-09
Place of Origin :
CN
MOQ :
1
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :
5000pcs
Delivery Time :
3-5work days
Packaging Details :
Paper box
Output voltage :
9-13 mV (in air)
Measurement range :
0 to 100%
Response time (T90) :
< 15 seconds
Accuracy :
± 1%
Temperature compensation :
< 2% O2 equivalent (0-40 ℃)
Load resistance :
≥10 kΩ
Description

AO-09 Oxygen Gas Sensor

Product Overview:
The AO-09 oxygen sensor is an electrochemical sensor specifically designed for measuring oxygen concentration in medical equipment. It adopts a molded body design and features rapid response and a long service life.

Full-range linear output
The operation does not require an external power supply
Temperature compensation
Quick response
Accurate and reliable
Strong anti-interference ability

Application scope:
The AO-09 oxygen sensor does not require an external power supply when in operation. It has all undergone professional and accurate product calibration and temperature compensation before leaving the factory
Sensing components for oxygen analyzers, such as oxygen generator control devices, medical ventilators, anesthesia equipment, incubators, etc.

Installation requirements:
When installing the sensor, it should be tightened by hand and ensure good air tightness. Do not use wrenches or similar mechanical auxiliary tools to prevent The thread of the stop sensor was damaged due to excessive force.

Storage and Use:
The AO-09 oxygen sensor should avoid exposure to high concentrations of organic solvent vapors during storage, installation and operation. When using sensors with printed circuit boards (PCBS), the PCB should be cleaned with a degreaser before installing the sensor to prevent rosin
Wait for the flux impurities to evaporate and condense, blocking the breathable membrane of the oxygen sensor. Organic solvents are prohibited on the sensor housing as they may cause the plastic to crack.

Cleaning:
If the sensor housing is contaminated, the sensor can be cleaned with distilled water and allowed to dry naturally. It is not allowed to use the sensor Sterilize with steam or expose the sensor to an environment containing chemicals such as ethylene oxide and hydrogen peroxide for a long time.

Temperature compensation < 2% O2 equivalent (0-40 ℃)
Load resistance ≥10 kΩ
Interface 3P 2.54
Shell material White ABS
Weight Approximately 40 grams
Operating temperature range 0 to 50 ℃
Working pressure range 0.5-2.0 Bar
Working humidity range 0-99% RH (no condensation)
Long-term drift in a 100% O2 environment 2 (Voltage attenuation/year) < 5%
Service life 1.5× 106% O2 hours (at 20 ℃) 3
0.8× 106% O2 hours (40 ℃)
Shelf life 13 months from the date of shipment

9-13 mV Output Voltage AO-09 Oxygen Gas Sensor for Real-time Oxygen Measurement

Send your message to this supplier
Send Now

9-13 mV Output Voltage AO-09 Oxygen Gas Sensor for Real-time Oxygen Measurement

Ask Latest Price
Model Number :
AO-09
Place of Origin :
CN
MOQ :
1
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :
5000pcs
Delivery Time :
3-5work days
Contact Supplier
9-13 mV Output Voltage AO-09 Oxygen Gas Sensor for Real-time Oxygen Measurement
9-13 mV Output Voltage AO-09 Oxygen Gas Sensor for Real-time Oxygen Measurement
9-13 mV Output Voltage AO-09 Oxygen Gas Sensor for Real-time Oxygen Measurement
9-13 mV Output Voltage AO-09 Oxygen Gas Sensor for Real-time Oxygen Measurement
9-13 mV Output Voltage AO-09 Oxygen Gas Sensor for Real-time Oxygen Measurement
9-13 mV Output Voltage AO-09 Oxygen Gas Sensor for Real-time Oxygen Measurement

ShenzhenYijiajie Electronic Co., Ltd.

Verified Supplier
4 Years
guangdong, shenzhen
Since 2006
Business Type :
Manufacturer, Trading Company
Total Annual :
900000-1000000
Employee Number :
50~80
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement