KGZ-NGL-096-273 Zirconia Oxygen Sensor
1. Overview:
- A flange-mounted zirconia oxygen sensor from UK-based SST, designed for sampling chambers. Favored by aerospace clients and applications requiring high-temperature and high-pressure operations.
2. Operating Conditions:
- Working Voltage: 4.35VDC ± 0.1VDC (1.85A)
- Standby Voltage: 2VDC (0.85A)
- Permissible Gas Temperature: -100°C to +250°C
- Gas Flow Rate: 0–10 m/s
3. Electrical Characteristics:
- Pump Impedance at 700°C: <6 kΩ
- Output Signal: Oxygen partial pressure measurement range: 2 mbar–3 bar, accuracy: ≤5 mbar
- Calibration-free design: No reference gas required; simple single-point calibration feasible in any known gas (including fresh air).
4. Temperature Characteristics:
- Internal Operating Temperature: 700°C
- Recommended Preheating Time: 60–100 seconds before sensor operation
- Output Stability Time: Stabilizes within 180 seconds after startup
5. Mechanical Characteristics:
- Repeated Allowable Acceleration: 5g
- Incidental Allowable Acceleration: 30g
- Termination: 0.4m cable with Molex connector
6. Other Features:
- Response Time (T90): <4 seconds
- Measurement Technology: Closed-loop measurement system. The sensor generates a "heartbeat" signal during continuous O₂ level monitoring, providing immediate fault warnings.
- Service Life: Up to 10 years (application-dependent), using non-depletable sensor cell technology.
- Structure: Zirconia (ZrO₂) sensing element, full stainless steel construction, flange-mounted, pin terminal.
- Environmental Adaptability: Operable in high-temperature, humid, and pressurized environments. Its robust structure allows use in harsh conditions, with no need to replace electronics at the end of the sensor's life.
Applications:
- Aerospace oxygen monitoring
- High-temperature industrial furnaces
- Combustion efficiency optimization systems
- Pressure vessel environment detection
Parameter | Value |
Model | KGZ-NGL-096-273 |
Manufacturer | SST (UK) |
Type | Flange-mounted zirconia oxygen sensor |
Sensing Principle | Zirconia (ZrO₂) electrochemical |
Measurement Range | Oxygen partial pressure: 2 mbar–3 bar |
Accuracy | ≤5 mbar |
Operating Voltage | 4.35VDC ± 0.1VDC (1.85A) |
Standby Voltage | 2VDC (0.85A) |
Gas Temperature Range | -100°C to +250°C |
Internal Working Temperature | 700°C |
Gas Flow Rate | 0–10 m/s |
Pump Impedance (700°C) | <6 kΩ |
Response Time (T90) | <4 seconds |
Preheating Time | 60–100 seconds |
Output Stability Time | Within 180 seconds after startup |
Acceleration Resistance | - Repeated: 5g - Incidental: 30g |
Cable & Connector | 0.4m cable with Molex connector |
Calibration Requirement | Single-point calibration (no reference gas needed) |
Service Life | Up to 10 years (application-dependent) |
Construction Material | Full stainless steel |
Mounting Method | Flange-mounted |