ES1-AG1-10 ES1-AG1-200 ES1-AG1-1000 Electrochemical VOC Gas Sensor
Basic Information:
- Detection Principle: Adopts EC Sense (Germany) solid-state polymer electrochemical detection technology. Based on electrochemical catalytic reaction, the sensor generates a micro-current signal proportional to the concentration of the target gas.
- Ordering Number: 01-ES1-AG1-10-01.
- Detected Gas: VOC (Volatile Organic Compounds).
Performance Parameters:
- Detection Range: 0 - 10ppm.
- Resolution: 0.01ppm.
- Sensitivity: 55±15nA/ppm (calibrated with C₄H₈).
- Working Principle: Amperometric, 3-electrode design.
- Temperature Range: -40°C to 55°C.
- Humidity Range: 10 - 95% RH (non-condensing).
- Pressure Range: 800 to 1200 hPa.
- Overload Capacity: 100ppm.
- Repeatability: 1%.
- Warm-up Time: Typically <60 seconds.
- Response Time: T50<10 seconds, T90<30 seconds.
- Weight: <0.7g.
- Dimensions: 11.5x11.5x5.5mm (pinless).
Additional Features:
- Long Service Life: >3 years.
- Anti-poisoning Capability.
- Zero Power Consumption.
- Linear Output.
- No Zero Drift.
- High Signal-to-Noise Ratio.
- Complies with RoHS standards.
Application Fields:
Applied to devices requiring VOC gas detection, such as air purifiers, to monitor VOC concentration in the environment and provide data support for air quality assessment and health protection.
Detected Gas |
VOC (Volatile Organic Compounds) |
Detection Range |
0 - 10ppm |
Resolution |
0.01ppm |
Sensitivity |
55±15nA/ppm (calibrated with C₄H₈) |
Working Principle |
Amperometric method, 3-electrode design |
Temperature Range |
-40°C to 55°C |
Humidity Range (Non-condensing) |
10 - 95% RH (Relative Humidity) |
Pressure Range |
800 - 1200 hPa (hectopascals) |
Overload Capacity |
100ppm |
Repeatability |
1% |
Warm-up Time |
<60 seconds |
Response Time |
T50<10s, T90<30s |
Weight |
<0.7g |