8412001 Flow Sensor Accessories
- Brand: Drager
- Model: 8412001
- Product Type: Possibly a gas filter, flow sensor, or battery component for anesthesia machines/ventilators (to be confirmed based on the equipment model)
- Applicable Equipment: Compatible with Drager series anesthesia machines (e.g., Fabius, Primus) or ventilators
- Purpose: May be used for gas filtration, flow monitoring, or equipment power supply
- Compatibility: Specifically designed for Drager equipment to avoid malfunctions due to interface mismatches;
- Safety: If it is a filter, it uses a hydrophobic membrane design to prevent liquid from entering the equipment; if it is a sensor, it has an anti-corrosion coating;
- Easy Maintenance: Supports plug-and-play, and some models can be automatically calibrated (e.g., filter replacement prompts, sensor zero-point calibration);
- Certifications: Complies with medical device standards such as CE and ISO 13485, and some models are FDA-certified.
- Anesthesia machine maintenance: Used to replace aging filters or sensors to ensure gas monitoring accuracy;
- Emergency backup: Battery components can maintain equipment operation for a short time during power outages to ensure surgical safety;
- Equipment calibration: New sensors need to be calibrated with standard gases (e.g., 21% O₂) after installation.
- Installation Method:
- Filter: Unscrew the equipment filter chamber and directly replace the old filter element;
- Sensor: Disconnect the power supply, plug in and replace, and complete initialization through the equipment menu;
- Battery: Disconnect the connection, install according to polarity, and charge for 4 hours when using for the first time.
- Replacement Cycle:
- Filter: Replace every 6 months or after 500 hours of use;
- Sensor: It is recommended to replace it every 1–2 years (depending on usage frequency and environment);
- Battery: Replace when the battery life drops to 80% of the rated value.
- Do not mix with non-original parts: Non-original accessories may cause equipment malfunctions or measurement deviations;
- Storage requirements: Filters should be stored in a dry and dust-free environment, and sensors should avoid contact with corrosive gases;
- Calibration requirements: After replacing the sensor, it must be calibrated with Drager original calibration gases (e.g., O₂, N₂O standard gases);
- Waste disposal: Medical-grade consumables should be discarded according to the hospital's infectious waste disposal procedures.
| Parameter Category | Possible Parameter Range |
| Filtration Efficiency (if filter) | - Particle filtration: ≥99.9% (0.3μm particles) - Bacterial filtration: ≥99.99% - Applicable gases: O₂, N₂O, air, and mixed anesthetic gases |
| Flow Measurement Range (if sensor) | - 0–200 L/min (common clinical range) - Accuracy: ±2% FS - Response time: ≤50ms |
| Battery Parameters (if battery) | - Type: Lithium battery - Capacity: ≥2000mAh - Operating voltage: DC 12V - Battery life: ≥4 hours (standby mode) |
| Interface Type | - Standard quick-connect/threaded interface compatible with Drager equipment mainboards or modules - Electrical interface: Pin-type or contact-type |
| Working Environment | - Temperature: 5°C–40°C - Humidity: ≤80% RH - Storage temperature: -20°C–50°C |