8410185 Sensors For Respiratory Anesthesia Machines Gas Sensor
- Brand: Drager
- Model: 8410185
- Product Type: Sensor for breathing anesthesia machines (specifically may be an oxygen sensor or flow sensor, subject to confirmation based on the equipment model)
- Applicable Equipment: Compatible with Drager series breathing anesthesia machines (such as Fabius, Primus, etc.)
- Origin: Germany (headquarters of Drager, with some components possibly produced in other countries)
- Measurement Range:
- If it is an oxygen sensor, the measurement range is usually 0%–100% O₂;
- If it is a flow sensor, the measurement range shall be determined according to the specific model, generally covering the clinically commonly used respiratory flow range (e.g., 0–150L/min).
- Accuracy:
- The accuracy of the oxygen sensor is usually ≤±2% FS (full scale);
- The accuracy of the flow sensor is ≤±3% of the reading or ±0.5L/min (taking the larger value).
- Response Time:
- Oxygen sensor: T90 (reaching 90% response) ≤10 seconds;
- Flow sensor: response time ≤50ms when the airflow changes.
- Operating Temperature: 5°C–40°C (in line with the environmental requirements of medical equipment)
- Interface Type: Dedicated plug-in interface, compatible with the mainboard or module of Drager equipment
- Power Supply Mode: Internal power supply of the equipment (usually DC 5V or 12V)
- High Accuracy: Adopts electrochemical or thermal measurement principles to ensure stable and reliable data, meeting the high-precision requirements of clinical anesthesia for gas concentration and flow.
- Anti-interference: The sensor design has the ability to resist water vapor and corrosion, reducing errors caused by anesthetic gases, moisture, and other factors in clinical use.
- Easy Maintenance: Supports hot-swap replacement without shutdown calibration, and some models have an automatic calibration function (such as zero and span calibration for oxygen sensors).
- Safety Certification: Complies with medical equipment certification standards such as CE and ISO 13485, and has passed biocompatibility tests to ensure patient safety.
- Breathing Anesthesia Machines: Used for real-time monitoring of parameters such as oxygen concentration and respiratory flow in the inhaled/exhaled gas of patients, providing data support for anesthetic depth control and ventilation management.
- Intensive Care Equipment: Some models can be compatible with intensive care ventilators to assist in monitoring gas parameters during mechanical ventilation.
- Installation Method: Directly insert into the sensor slot of the equipment, fix it with a buckle or screw, and use it after completing calibration according to the instructions.
- Replacement Cycle:
- Oxygen sensor: It is generally recommended to replace it every 1–2 years (affected by usage frequency and environment);
- Flow sensor: There is no clear replacement cycle. If the measurement deviation exceeds the range or a fault code appears, it needs to be replaced in a timely manner.
- Calibration Requirements: Standard gases (such as 21% O₂, 100% O₂) are required for calibration when installing for the first time or regularly (such as every 6 months).
- No Disassembly: The interior of the sensor is a precision component. Disassembly by non-professionals may cause damage or measurement failure.
- Storage Conditions: Store in a dry environment without corrosive gases, at a temperature of 0°C–30°C and a humidity of ≤80%RH.
- Compatibility: Only applicable to the specified models of Drager equipment. Do not mix it with equipment of other brands.
- Packaging: Independent anti-static packaging, including instructions and a calibration certificate.
- Certifications: International medical certifications such as CE, ISO 13485, and FDA (if applicable).
Parameter | Details |
Brand | Drager |
Model | 8410185 |
Product Type | Sensor for breathing anesthesia machines (possibly oxygen/flow sensor, subject to equipment model) |
Applicable Equipment | Drager Fabius, Primus series anesthesia machines |
Origin | Germany |
Measurement Range | - Oxygen sensor: 0%–100% O₂ - Flow sensor: 0–150L/min (typical clinical range) |
Accuracy | - Oxygen sensor: ≤±2% FS - Flow sensor: ≤±3% of reading or ±0.5L/min (whichever is larger) |
Response Time | - Oxygen sensor: T90 ≤10s - Flow sensor: ≤50ms (to airflow changes) |
Operating Temperature | 5°C–40°C |
Interface Type | Dedicated plug-in interface for Drager equipment |
Power Supply | Internal DC power (5V/12V) |
Material | Corrosion-resistant sensor element with anti-moisture design |
Calibration Requirement | Standard gas calibration (21% O₂, 100% O₂) required for first installation and every 6 months |
Replacement Cycle | - Oxygen sensor: 1–2 years (usage-dependent) - Flow sensor: As needed (when deviation exceeds range) |
Safety Certification | CE, ISO 13485, FDA (if applicable) |
Packaging | Anti-static independent package with calibration certificate |
Storage Conditions | 0°C–30°C, ≤80% RH, dry environment |
Compatibility | Exclusive for Drager specified anesthesia machine models |