8417050 Repetitive Exhalation Valve Of Ventilator
- Product Name:Reusable Expiratory Valve
- Model:8417050
- Compatible Equipment:Drager Savina 300 ventilator
- Brand:Drager
- Dimensions:Approx. 10cm × 20cm
- Weight:Lightweight (unspecified, designed for easy installation without burdening the ventilator)
- Working Principle:Mechanically controls gas outflow to regulate oxygen flow rate by adjusting the position of the valve core and stem, changing the length of the airflow channel.
- Gas Exchange:Facilitates exhalation of carbon dioxide and inhalation of fresh gas to maintain physiological gas exchange.
- Monitoring & Protection:Built-in sensors continuously monitor respiratory status (e.g., breathing presence, exhaled gas concentration). Alerts the ventilator system immediately in case of abnormalities for emergency intervention.
- Sealability:High-sealing design prevents air leakage during exhalation (leakage rate ≤ 5mL/min under normal pressure), ensuring ventilator functionality.
- Response Speed:Valve reaction time ≤ 5ms, enabling rapid adaptation to patient breathing for timely respiratory support.
- Power Supply:No external power required; operated by the ventilator's integrated power system.
- Control Method:Mechanical control via structural design for valve opening/closing and flow regulation.
- Certifications:Complies with medical standards (CE, ISO 13485) for safety and quality assurance.
- Service Life:Durable under normal use (specific lifespan unspecified; regular inspection and replacement recommended per hospital maintenance protocols).
- Cleaning & Maintenance:Reusable; requires standard Drager cleaning and disinfection procedures (e.g., periodic cleaning to prevent sputum/blood accumulation affecting functionality).
Parameter | Details |
Product Name | Reusable Expiratory Valve |
Model | 8417050 |
Compatible Equipment | Drager Savina 300 ventilator |
Brand | Drager |
Dimensions | Approx. 10cm × 20cm |
Weight | Lightweight (unspecified) |
Working Principle | Mechanically controls gas outflow by adjusting valve core and stem to change airflow channel length, regulating oxygen flow rate. |
Gas Exchange Function | Facilitates exhalation of CO₂ and inhalation of fresh gas to maintain physiological gas exchange. |
Monitoring & Protection | Built-in sensors monitor respiratory status (breathing presence, exhaled gas concentration) and alert the ventilator in case of anomalies. |
Sealability | High-sealing design prevents air leakage (leakage rate ≤ 5mL/min under normal pressure). |
Response Speed | Valve reaction time ≤ 5ms |
Power Supply | No external power required (operated by ventilator's integrated system). |
Control Method | Mechanical control |
Certifications | Complies with CE, ISO 13485 and other international medical device standards. |
Service Life | Durable under normal use (specific lifespan unspecified; regular inspection/replacement recommended per hospital protocols). |
Cleaning & Maintenance | Reusable; requires standard Drager cleaning and disinfection procedures. |