H2S-100 4R+ C03-0907-001 Hydrogen Sulfide Sensor for Personal & Portable Safety Industrial Process Safety
Key Features:
- High accuracy & resolution: Electrochemical sensing with 0.1 ppm resolution and ±2% FS accuracy at 20°C, ensuring precise low level H2S detection.
- Fast response & stability: T90 ≤ 30 seconds; long term drift < 2% signal/month for consistent readings with minimal recalibration.
- Robust environmental tolerance: Operates from -20°C to 50°C (-4°F to 122°F), 15~90% RH non condensing, and ±10% atmospheric pressure, suitable for harsh field conditions.
- Plug and play integration: No bias voltage needed; 10 minute equilibration after installation enables quick replacement in RAE Systems monitors.
- Long operational life: 2-year life in air, 6-month shelf life in sealed packaging, and 2-year warranty for cost effective maintenance.
- Safety & compliance: Intrinsically safe design (max current <1 mA at 500 ppm H2S) for use in explosive atmospheres when paired with certified monitors.
Product Applications:
- Personal & portable safety: Used in ToxiRAE Pro, MultiRAE, AreaRAE, and QRAE series monitors for workers in oil & gas, wastewater, mining, and confined spaces to protect against H2S exposure.
- Industrial process safety: Monitoring H2S in refineries, petrochemical plants, biogas facilities, and landfill operations to prevent toxic gas buildup and ensure regulatory compliance.
- Environmental & wastewater: H2S emission monitoring in sewers, treatment plants, and anaerobic digestion systems to manage odor and worker safety.
- Confined space entry: Pre entry and continuous monitoring of manholes, tanks, and vaults where H2S can accumulate to lethal levels.
- Fixed gas detection integration: Compatible with RAEGuard, MeshGuard, and VRAE fixed systems for 24/7 area monitoring in non hazardous and hazardous zones (with proper certification).
|
Parameter Category
|
Parameter
|
| Basic Info |
Model |
| |
Sensor Type |
| |
Brand |
| |
Certification |
| Measurement Performance |
Range |
| |
Max Overload |
| |
Resolution |
| |
Accuracy |
| |
Response Time (T90) |
| |
Sensitivity (20°C) |
| |
Baseline (20°C) |
| |
Long-term Drift |
| Electrical Characteristics |
Bias Voltage |
| |
Max Current (500 ppm H2S) |
| |
Max Open-Circuit Voltage |
| |
Max Short-Circuit Current |
| Environmental & Physical |
Operating Temp |
| |
Storage Temp |
| |
Pressure Range |
| |
Humidity |
| |
Operating Life |
| |
Storage Life |
| |
Weight |
| |
Warranty |
| Compatibility |
Compatible Monitors |
| |
Calibration Gas |