10145738-SP MSA Infrared (IR) CO2 Sensor Kit (with Shield) for Industrial Process Control Confined Space Safety
Applications:
- Respiratory protection: CO2 monitoring in self contained breathing apparatus (SCBA) for firefighters and industrial workers.
- Confined space safety: Detecting CO2 buildup in tanks, tunnels, and underground facilities.
- Industrial process control: Monitoring CO2 levels in food/beverage production, fermentation, and HVAC systems.
- Environmental monitoring: Indoor air quality (IAQ) assessment in commercial buildings and laboratories.
Key Features:
- High Measurement Range: 0–10 Vol% (100,000 ppm) for comprehensive CO2 monitoring.
- Fast Response: T90 ≤ 15 seconds for real time leak alerts and safety intervention.
- Robust Shield Design: Integrated shield protects against dust, moisture, and physical damage, suitable for harsh industrial settings.
- Low Power Consumption: Optimized for portable and battery powered devices, extending operational runtime.
- Plug and Play Compatibility: Designed for seamless integration with MSA Ultra Elite facepieces and gas monitoring systems.
| Target Gas |
Carbon Dioxide (CO2) |
| Detection Range |
0–10 Vol% (0–100,000 ppm) |
| Accuracy |
±0.1 Vol% or ±5% of reading (whichever is greater) |
| Response Time (T90) |
≤ 15 seconds |
| Operating Temperature |
-20°C to +50°C |
| Storage Temperature |
-30°C to +60°C |
| Humidity Range |
15–95% RH (non condensing) |
| Power Requirements |
5 VDC, 100 mA (max.) |
| Output Signal |
Analog (0–5 VDC) proportional to CO2 concentration |
| Form Factor |
Compact, with integrated shield for easy installation |
| Weight |
~150 g (including shield) |