SMD1015 Detection Of Exhaled Content Using Gas Sensor
Applications:
The SMD1015 gas sensor is primarily utilized for detecting gas. It finds extensive use in various fields:
- Medical Field: It can be employed in breath analysis devices to detect levels in exhaled breath. Changes in concentration in breath can be indicative of certain metabolic conditions, such as in the monitoring of diabetes, where abnormal levels may occur.
- Industrial Safety: In industries where is used as a solvent or in manufacturing processes, this sensor helps in monitoring leaks to ensure workplace safety and prevent potential hazards.
- Environmental Monitoring: It can be integrated into environmental monitoring systems to detect emissions from industrial sources, contributing to the assessment and control of air pollution.
Features:
- High Sensitivity: With a resolution of 0.1 ppm and a sensitivity of R₀ (in air) / Rₛ (in 1 ppm C₂H₆O) ≥ 1.5, the sensor can accurately detect even low concentrations of, enabling precise measurement.
- Wide Detection Range: It can detect within the range of 0 - 500 ppm, making it suitable for both low - concentration and relatively high - concentration detection scenarios.
- Good Environmental Adaptability: The sensor operates within a temperature range of -20 - 55 °C and a humidity range of 10 - 95% RH, allowing it to function reliably in various environmental conditions.
- Fast Response and Recovery: The response time (T₉₀) is less than 30 seconds, and the recovery time (T₁₀) is less than 60 seconds, ensuring quick detection and recovery after exposure to gas.
- Long Service Life: With a service life of ≥3 years, the sensor provides long - term and stable performance, reducing the need for frequent replacement.
- MEMS Technology: Based on MEMS (Micro - Electro - Mechanical Systems) semiconductor technology, the sensor has the advantages of small size, low power consumption, and high integration, facilitating its integration into various devices.
| Product Model | SMD1015 |
| Product Type | MEMS Semiconductor Sensor |
| Standard Package | Ceramic Package |
| Detection Concentration | 0 - 500 ppm |
| Resolution | 0.1 ppm |
| Operating Temperature | -20 - 55 °C |
| Operating Humidity | 10 - 95% RH |
| Standard Circuit Conditions | |
| Circuit Voltage (VC) | 5 V or 3.3 V |
| Heating Voltage (VH+) | 1.8 V ± 0.1 V AC/DC |
| Load Resistance (RL) | Adjustable (subject to delivery report) |
| Gas - Sensitive Element Characteristics Under Standard Test Conditions | |
| Heating Resistance (RH) | 45 Ω ± 5 Ω (at room temperature) |
| Heating Power Consumption (PH) | ≤30 mW |
| Sensitive Body Resistance (R0) | 10 KΩ - 1000 KΩ (in air) |
| Sensitivity (S) | R₀ (in air) / Rₛ (in 1 ppm C₂H₆O) ≥ 1.5 |
| Slope (α) | ≤0.5 (R3ppm / R1ppm C₂H₆O) |
| Standard Test Conditions | |
| Temperature, Humidity | 20 °C ± 2 °C; 55% ± 5% RH |
| Standard Test Circuit | Vcc: 5 V or 3.3 V; VH: 1.8 V ± 0.1 V (maximum 2.2 V can be used to shorten preheating time) |
| Preheating Time | 3 - 5 min |
| Response Time (T₉₀) | < 30 s |
| Recovery Time (T₁₀) | < 60 s |
| Service Life | ≥3 years |