Specifications
Model Number :
4OX-V-CN 4OXV-CN AAY80-390-CN
Place of Origin :
CN
MOQ :
1
Price :
Negotiable
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :
5000pcs
Delivery Time :
3-5work days
Packaging Details :
Paper box
Measurement Range :
1 - 25% vol. O₂
Maximum Overload :
30% vol. O₂
Output Signal :
0.10 ± 0.02 mA in air
Response Time (T90) :
< 15 seconds
Zero Current (Offset) :
< 0.6% vol. O₂
Pressure Coefficient :
< 0.02% signal/mbar
Description

4OX-V-CN 4OXV-CN Gas Oxygen Sensor False Alarm Immunity Reliably Meets Stated Life

Features:

  • False alarm immunity.
  • Enhanced response time in extreme applications.
  • Reliably meets stated life.
  • Superior environmental performance.

Applications:

  • General purpose, portable or fixed life safety.

Measurement Technology Electrochemical
Measurement Range 1 - 25% vol. O₂
Maximum Overload 30% vol. O₂
Output Signal 0.10 ± 0.02 mA in air
Response Time (T90) < 15 seconds
Zero Current (Offset) < 0.6% vol. O₂
Linearity Can be considered linear in many cases
Operating Temperature Range - 20 °C to + 50 °C (up to 3 months continuous across RH range)
Recommended Storage Temp 0 °C to 20 °C
Thermal Transient < 23.5% vol. O₂ (temp. plunge + 22 °C to - 20 °C)
Operating Pressure Range Atmospheric ± 20%
Pressure Coefficient < 0.02% signal/mbar
Pressure Transient < 200% signal change (60 cm H₂O step change)
Relative Humidity Range (at 0 °C to 20 °C) Continuous: 5 to 95% RH non - condensing; Short term: 0 to 99% RH non - condensing
Recommended Load Resistor 100 Ω
Casing Material ABS
Weight < 16 g
Orientation Sensitivity < 0.2% vol. O₂ equivalent
Long - term Output Drift < 2% signal/month, typically < 5% over operating life

4OX-V-CN 4OXV-CN AAY80-390-CN Gas Oxygen Sensor False Alarm Immunity Reliably Meets Stated Life

Send your message to this supplier
Send Now

4OX-V-CN 4OXV-CN AAY80-390-CN Gas Oxygen Sensor False Alarm Immunity Reliably Meets Stated Life

Ask Latest Price
Model Number :
4OX-V-CN 4OXV-CN AAY80-390-CN
Place of Origin :
CN
MOQ :
1
Price :
Negotiable
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :
5000pcs
Contact Supplier
4OX-V-CN 4OXV-CN AAY80-390-CN Gas Oxygen Sensor False Alarm Immunity Reliably Meets Stated Life
4OX-V-CN 4OXV-CN AAY80-390-CN Gas Oxygen Sensor False Alarm Immunity Reliably Meets Stated Life
4OX-V-CN 4OXV-CN AAY80-390-CN Gas Oxygen Sensor False Alarm Immunity Reliably Meets Stated Life

ShenzhenYijiajie Electronic Co., Ltd.

Verified Supplier
4 Years
guangdong, shenzhen
Since 2006
Business Type :
Manufacturer, Trading Company
Total Annual :
900000-1000000
Employee Number :
50~80
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement