ET48300 19 Inch Telecommunication Power System with RS485 Remote Monitoring
Product Overview of 18kw 96% Efficiency Telecommunication Power System
The ET48300-M5S65 DC rack power system provides a high-capacity, resilient DC power solution designed specifically for telecommunications infrastructure, data center operations, and industrial applications requiring dependable DC power distribution. It accepts 220VAC 125A/2P (dual live-line supported) input and delivers a stable DC output adjustable between –43VDC to –58VDC, with a nominal operating point of –53.5VDC. Offering a maximum output capacity of 18kW, this system reliably supports high-demand installations while achieving power conversion efficiency exceeding 96%.
The DC distribution panel is equipped with 2*125A/1P battery circuit breakers and includes LLVD & BLVD functionality for secure and flexible power management. System intelligence is provided by a dedicated controller featuring 3 analog sensor inputs, 7 digital status inputs, and 6 configurable dry-contact alarm relays. Remote monitoring and management are enabled via RS232/485 and SNMP interfaces, while an integrated LCD display allows for local status viewing and configuration.

Rectifier Module of 18kw 96% Efficiency Telecommunication Power System
Featuring a modular and redundant design, the system supports up to 6*3000W rectifier modules configured for N+1 redundancy, with each compact module weighing under 2kg. The rectifiers utilize forced-air cooling, achieve a near-unity power factor (≥0.99), and maintain low total harmonic distortion (THDi ≤5%) for efficient and clean power conversion. With front-access maintenance, top-panel cabling, and IP20 ingress protection, the 3U rack-mountable chassis emphasizes operational safety, ease of service, and straightforward integration into standard 19-inch cabinets.
of 18kw 96% Efficiency Telecommunication Power System
The ET48300-M5S65 DC rack power system provides a high-capacity, resilient DC power solution designed specifically for telecommunications infrastructure, data center operations, and industrial applications requiring dependable DC power distribution. It accepts 220VAC 125A/2P (dual live-line supported) input and delivers a stable DC output adjustable between –43VDC to –58VDC, with a nominal operating point of –53.5VDC. Offering a maximum output capacity of 18kW, this system reliably supports high-demand installations while achieving power conversion efficiency exceeding 96%.
The DC distribution panel is equipped with 2*125A/1P battery circuit breakers and includes LLVD & BLVD functionality for secure and flexible power management. System intelligence is provided by a dedicated controller featuring 3 analog sensor inputs, 7 digital status inputs, and 6 configurable dry-contact alarm relays. Remote monitoring and management are enabled via RS232/485 and SNMP interfaces, while an integrated LCD display allows for local status viewing and configuration.

Rectifier Module of 18kw 96% Efficiency Telecommunication Power System
Featuring a modular and redundant design, the system supports up to 6*3000W rectifier modules configured for N+1 redundancy, with each compact module weighing under 2kg. The rectifiers utilize forced-air cooling, achieve a near-unity power factor (≥0.99), and maintain low total harmonic distortion (THDi ≤5%) for efficient and clean power conversion. With front-access maintenance, top-panel cabling, and IP20 ingress protection, the 3U rack-mountable chassis emphasizes operational safety, ease of service, and straightforward integration into standard 19-inch cabinets.
Advantages of 18kw 96% Efficiency Telecommunication Power System
Wide range AC input (85VAC~300VAC) - Operates through severe brownouts and overvoltage events without switching to battery
>96% efficiency – Minimizes heat generation and electricity costs
3000W output from 176~300VAC input – High power density in 1U form factor
-40℃ to +75℃ operating range – Full rated output below 50℃, reliable in extreme climates
≥0.99 power factor & ≤5% THD – Grid-friendly operation with minimal harmonic distortion
Specifications of 18kw 96% Efficiency Telecommunication Power System
| Type |
ET48300-M5S65 |
| System |
Dimension |
482.6(W)*350.0(D)*5U(H) |
| Weight |
≤25kg (without rectifiers) |
| Cooling mode |
Natural cooling |
| Installation mode |
Installed on 19-inch rack or inside the cabinet |
| Cabling mode |
Top inlet and top outlet |
| Maintenance mode |
Front maintenance, support module grade change |
| Protection level |
IP20 |
AC
Distribution |
Input mode |
220VAC 125A/2P (dual live-line supported) |
| Input frequency |
45~65Hz, rated value: 50Hz/60Hz |
|
AC SPD
|
20kA/40kA, 8/20μs |
DC
Distribution |
Output voltage |
-43~-58VDC, rated value: -53.5VDC |
| Maximum capacity |
18kW(6*3kw, N+1 redundancy) |
| Battery breakers |
2*125A/1P |
| Load breakers |
LLVD: 2*63A/1P+4*100A*1P
BLVD: 3*16A/1P+3*32A/1P
|
| DC SPD |
10kA/20kA, 8/20μs
|
| Rectifier |
Input voltage |
85VAC~300VAC, rated 220VAC |
| Efficiency |
>96% |
| Rated power |
3000W(176~300VAC) |
| Working temperature |
-40℃~+75℃(fully output below 50℃) |
| Dimension |
106.5mm(W)×286mm(D)×41.5mm(1U/H) |
| Weight |
≤2kg |
| Cooling mode |
Forced cooling |
| Power factor |
≥0.99 |
| THD |
≤5% |
| DC output |
–43 ~ –58VDC, rated –53.5VDC, maximum 55A |
| Controller |
Signal input |
3 AI (3 ambient temp), 7 DI |
| Alarm output |
6 dry contact |
| Communication port |
RS232/485, SNMP |
| Display mode |
LCD |
| Environment |
Operating
temperature |
-40℃ ~ +65℃ (full output below 50℃) |
| Storage temperature |
-40℃~+70℃ |
| Operating humidity |
5%~95%(non-condensing) |
| Altitude |
0~3000m(If the altitude is within the range of 2000m to 3000m, the maximum operating
temperature decreases by 1℃ as the altitude increases by 200m.) |