Overview


Here is a collection of specifications derived from the sources:
| Parameter | Value / Range | 
|---|---|
| Supported bandwidths (LTE) | 1.4, 3, 5, 10, 15, 20 MHz | 
| Operating frequency bands | 850 MHz, 1800 MHz, 2100 MHz, 2600 MHz (some models) | 
| Transmit / Receive configuration | 2T4R (2 transmit, 4 receive) | 
| Maximum transmit power | 2 × 60 W (i.e. two transmit channels each 60 W) | 
| Power supply | DC: –48 V (range: –37 V to –60 V) AC: 110/220 V (range: 90 V to 290 V)  |  
| Interfaces / backhaul | CPRI interface (optical SFP, LC) with rates: 1.25, 2.5, 3, 6 Gbps (CPRI v4.2) | 
| Physical dimensions | ~422 × 218 × 133 mm (H × W × D) for common bands (Type I) | 
| Weight | ~14 to 15 kg (without sunshield) | 
| Environmental / Temperature | Operating: –40 °C to +55 °C Storage: –40 °C to +70 °C Relative Humidity: up to 100% (condensing) Protection: IP65 rating  |  
| Surge / Lightning protection | DC power interface: 20 kA (line-to-ground and line-to-line)  Antenna interface: 10 kA line-to-ground  |  
| Power consumption | In GSM single mode: typical ~290 W, peak ~410 W  In UMTS single mode: typical ~240 W, peak ~355 W In GSM/UMTS dual mode: typical ~330 W, peak ~410 W  |  
| Reliability / Availability | Availability: 99.999689%  MTBF: ~322,000 hours MTTR: ~1 hour  |  
| Other features | - Transmit power reporting per carrier - Load protection for PA - Channel on/off switching - Software failure isolation (doesn’t affect BBU operation)  |  