| Switching Capacity |
336Gbps |
336Gbps |
336Gbps |
| Packet Forwarding Rate |
96Mpps |
96Mpps |
96Mpps |
| Dimensions
(W × D × H, mm) |
440×260×44 |
440×260×44 |
440×400×44 |
| Weight |
≤3.4kg |
≤3.4kg |
≤4.0kg |
| Installation Method |
Rack mounting |
Rack mounting |
Rack mounting |
| Cable Outlet Mode |
Rear / single-side outlet |
Dual-side outlet |
Dual-side outlet |
| Power Interface |
Phoenix terminal |
Phoenix terminal |
AC: IEC 60320 C13;
DC: Phoenix terminal |
| Configuration Port |
1 × RJ45 Console |
1 × RJ45 Console |
1 × RJ45 Console |
| Alarm / DI/DO |
1 normally open ALM alarm port;
1 normally closed Fail alarm port |
1 DI: 0 = -30~3V, 1 = 13~30V;
1 DO: 250VAC 1A Max / 220VDC 60W Max |
1 normally open ALM alarm port;
1 normally closed Fail alarm port |
| Protection Rating |
IP40 |
IP40 |
IP31 |
| Service Ports |
24 × 10/100BASE-T electrical ports,
4 × 100/1000BASE-X SFP ports |
24 × 100BASE-X SFP ports,
2 × 10/100/1000BASE-T electrical ports,
2 × 100/1000BASE-X SFP ports |
24 × 100BASE-X SFP ports,
2 × 10/100/1000BASE-T electrical ports,
2 × 100/1000BASE-X SFP ports |
| Power Input |
Dual redundant power input
AC: 100–240VAC, 50/60Hz (Max: 90–264VAC);
or DC110V/DC220V: 88–264VDC |
Dual redundant power input
24~48VDC (12~60VDC) |
Dual AC/DC redundant power input
AC: 100–240VAC, 50/60Hz (Max: 85–264VAC);
DC220V: 192–288VDC;
24~48VDC (18~55VDC) |
| Static Power Consumption |
≤8.6W |
≤6.8W |
≤15W |
| Full-load Power Consumption |
≤13.5W |
≤10.8W |
≤32W |
| Heat Dissipation |
Fanless, natural heat dissipation |
Fanless, natural heat dissipation |
Fanless, natural heat dissipation |
| Operating Humidity |
5%~95% (Non-condensing) |
5%~95% (Non-condensing) |
5%~95% (Non-condensing) |
| Operating Temperature |
-40℃~75℃ |
-40℃~75℃ |
-40℃~70℃ |
| Storage Temperature |
-40℃~85℃ |
-40℃~85℃ |
-40℃~85℃ |