Specifications
Brand Name :
HUATEC
Model Number :
HFV-2206M
Certification :
CE
Place of Origin :
China
MOQ :
1 pc
Price :
USD955/set - USD1080/set
Payment Terms :
T/T,Paypal
Supply Ability :
10sets/Month
Delivery Time :
7-10 working days after receipt of your payment
Packaging Details :
Carton packing box
Maximum Light Intensity :
>70,000 Cd/㎡
Film density :
<4.0D According to the inspection report
Surface temperature :
<18°Celsius Continuous operation for 24 hours)
Uniform Viewing Area :
98% Full Screen
Dimmer Control :
0% to 100% continuous
Control mode :
Manual + Foot-switch
Description

HFV-2206M Portable Industrial X-ray Film Viewer Integrated Densitometer Foot Switch Adjustable Brightness NDT Testing Equipment


Features:

Maximum Light Intensity: > 70,000cd/㎡

Easily View < 4. 0 Density

Pure White LED Light

50,000 Hour Lamp Life

Low Power Consumption

Fan cooling

Foot Switch

Uniform Viewing Area: 98% Full Screen

Dimmer Control: 0% to 100% continuous

Surface temperature: <18°

Built-desktop stand

Design: Modern, Stylish and Simple

Power Requirements: 85-264VAC/47-60Hz

The power adapter: AC: 90-264VAC / 47-63Hz DC: 12V 5A

Safety Regulation and Electromagnetic Compatibility


Specifications:

Adapter Input voltage 85-264VAC / 47-60Hz DC: 12V 5A Power: 60W
Maximum Light Intensity >70,000 Cd/㎡
Film density <4.0D According to the inspection report
Surface temperature <18°Celsius Continuous operation for 24 hours)
Uniform Viewing Area 98% Full Screen
Dimmer Control 0% to 100% continuous
Control mode Manual + Foot-switch
Cooling Method Forced air cooling
Dimensions 425mm*60mm*130 mm (L*W*H)
Viewer window 220mm*60mm (L*W)
Viewing-mask window 200 mm*40 mm (L*W)
Power 50W
Weight 2.5 KG


Package Contents:

LED viewer with densitometer HFV-2260M 1pc

Foot switch 1pc

AC power cord 1pc

Viewing mask 1pc

Magnetic film holder 2pcs

Magnetic ruler 1pc

User's manual 1pc

Calibration certificate 1pc


Trouble Cause of the fault:

The power light is not on Elimination method: Check the power switch (8) to see if it is on the position of the foot switch, if is, should use in the foot switch mode. Check the lightness adjustment knob on the right-side control penal to see if it is on the minimum position, it is, should turn it to the proper lightness in the clockwise.

HFV-2206M Portable Industrial X-ray Film Viewer Integrated Densitometer Foot Switch Adjustable Brightness NDT Testing Equipment

Send your message to this supplier
Send Now

HFV-2206M Portable Industrial X-ray Film Viewer Integrated Densitometer Foot Switch Adjustable Brightness NDT Testing Equipment

Ask Latest Price
Brand Name :
HUATEC
Model Number :
HFV-2206M
Certification :
CE
Place of Origin :
China
MOQ :
1 pc
Price :
USD955/set - USD1080/set
Contact Supplier
HFV-2206M Portable Industrial X-ray Film Viewer Integrated Densitometer Foot Switch Adjustable Brightness NDT Testing Equipment
HFV-2206M Portable Industrial X-ray Film Viewer Integrated Densitometer Foot Switch Adjustable Brightness NDT Testing Equipment

HUATEC GROUP CORPORATION

Verified Supplier
11 Years
beijing, beijing
Since 2007
Business Type :
Manufacturer, Distributor/Wholesaler, Exporter, Seller
Total Annual :
500000-1000000
Employee Number :
35~50
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement