Aluminum Electric Cable 0.6/1kV PVC Insulation Waterproof IP66 Armored Type for Construction Work
Product Construction
- Conductor: Solid or stranded copper/aluminum
- Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)
- Filler: Polypropylene filament with lapped binding tape
- Binder: Binding tape
- Inner sheath: Polyvinyl chloride (PVC)
- Armouring: Single Core: AWA (Aluminium Wire Armour)
Multi Core: SWA (Steel Wire Armour) STA (Steel Tape Armour)
Applications
Copper aluminum conductor, XLPE insulated, tape armoured and PVC sheathed. Suitable for installations indoors and outdoors including:
- Power supply stations
- Cable ducts and underground installations
- Cable trays for industries
- Switch-boards and power stations
Due to excellent laying and mechanical characteristics, this cable is ideal where mechanical protection is required or where mechanical damages are expected to occur.
Key Features
High Temperature Resistance
XLPE insulation maintains performance at 90°C with lifespan up to 40 years
Excellent Insulation
Superior insulation resistance and electrical performance
Mechanical Strength
Enhanced hardness, stiffness, wear and impact resistance
Chemical Resistance
Strong resistance to acids, alkalis, and oils
Environmental Safety
Low environmental pollution, meets fire safety requirements
Temperature Ratings
Maximum conductor temperature: 90°C normal, 250°C short circuit (≤5s)
Technical Specifications
Insulated PVC/XLPE sheathed power cable for power transmission and distribution systems with rated voltages of 0.6/1, 1.8/3, 3.6/6, 6/10, 8.7/10, 8.7/15, 12/20, 21/35, 26/35KV.
| Cable Type |
Application |
| YJV, YJLV (XLPE insulated, PVC sheathed) |
Indoors, tunnels, pipes, buried in soil (not subject to mechanical force) |
| YJV22, YJLV22 (XLPE insulated, steel tape armored) |
Indoor, tunnel, pipe penetration, buried in soil |
| YJV32, 42, YJLV32, 42 (XLPE insulated, steel wire armored) |
Shafts, water, places with drop, can withstand external forces |
Operating Conditions
| Parameter |
Specification |
| Maximum Conductor Temperature (Normal Operation) |
70°C for PVC insulation, 90°C for XLPE insulation |
| Maximum Conductor Temperature (Short Circuit ≤5s) |
PVC: 160°C (≤300mm²), 140°C (>300mm²) XLPE: 250°C |
| Minimum Installation Temperature |
0°C |
| Minimum Bending Radius |
Single core: unarmored 20D, armored 15D Multi-core: unarmored 15D, armored 12D (D = cable outer diameter) |
| Cable Breaking Force |
Aluminum core: 40*S (N) Copper core: 70*S (N) |