YC-1891D-24  Single-phase Electric Energy Meter Testing System
 GENY's electric energy meter test benches are renowned for their:
 
 1. Exceptional power source stability 20~50 ppm: Ensuring reliable operation and accurate testing results.  
2. Excellent parameters: Distortion factor < 0.3% : Meeting or exceeding IEC international standards, providing clients with precise testing capabilities.  
2. Power output capabilities,Current output up to 200A;   Power up to 3000VA
3.High customization: Designed and manufactured according to specific client requirements, adaptable to diverse application scenarios.   
    - Measurement methods: active power, reactive power, active energy, reactive energy
  -  Starting and diving test
  -  Automatic labelling, easy to quickly carry out the diving, start-up test
  -  Measurement of basic error, average error, standard deviation, 24h variation
  -  Voltage effect, frequency effect, harmonic effect 2-21 times, phase sequence effect test
  -  Simultaneous current measurement on the same meter frame
  -  The current and voltage circuits of the measured energy meter can be tested without decoupling.
  -  With open-circuit current and short-circuit voltage protection function
  -  Collector flip function of photoelectric head improves the working efficiency.
  -  Electric and manual operation modes
  -  Computer software automatically realises error data processing and sorting, data storage and online output
  -  Data management function, printing reports in various formats according to the user's needs.
  -  Support barcode input
  -  Simple and reliable mechanical structure
  -  From 3 tables to 60 tables for customer's choice
  
   
 Product Parameters
 
     |   Main Technical Indicators   |    Parameter Value   |  
  |   Power Supply   |    AC220V±10%, 50Hz±2Hz   |  
  |   Ambient Temperature   |    -10°C ... +40°C   |  
  |   Ambient Humidity   |    35% ... 95%   |  
  |   Output Voltage Range   |    24V ... 288V   |  
  |   Output Voltage Power   |    1000VA (Max)   |  
  |   Voltage Resolution   |    0.01%   |  
  |   Voltage Stability   |    0.02%/120s   |  
  |   Load Change Rate   |    0.01%   |  
  |   Voltage Distortion   |    ≤0.3% (Full linear load range)   |  
  |   Output Current Range   |    1mA ... 120A (Up to 230A Max)   |  
  |   Output Current Power   |    2000VA (Max)   |  
  |   Current Resolution   |    0.01%   |  
  |   Current Stability   |    0.02%/120s   |  
  |   Load Change Rate   |    0.01%   |  
  |   Current Distortion   |    ≤0.3% (Full linear load range)   |  
  |   Continuous Current   |    100A   |  
  |   Phase Adjustment Range   |    0° ... 360°   |  
  |   Phase Resolution   |    0.01°   |  
  |   Frequency Adjustment Range   |    45Hz ... 65Hz   |  
  |   Frequency Resolution   |    0.01Hz   |  
  |   Power Output Stability   |    0.02%/120s   |  
  
   
 
 
 
 
 