1.Meter Test System: Measures mechanical, electronic mechanical, and electronic meters (3P4W, 3P3W, 1P2W) in automatic, semi-automatic, or manual modes.
2.Testing Modes: Active power, reactive power, cross-connected reactive power.
3.Functions: Simultaneous testing of meters with different constants; starting and creeping tests; optional neutral current test.
4.Features: Automatic rotor mark positioning for mechanical meters; overload, short-circuit, and open-circuit protection.
5.Design: Synchronized scanning heads for simplified control; aluminum alloy material (lightweight, strong, corrosion-resistant).
6.Software: Windows-compatible (2000/XP/7/8/10); modules for error, harmonic, demand, and influence tests.
|   Technical spec.  |    |  
|   Number of meter positions  |    24  |  
|   Accuracy  |    0.05 / 0.02  |  
|   Power Source  |    YCS-103-1200  |  
|   Standard Meter  |    SZ03A-K6 / SZ03A-K8 / Radian RD-33  |  
|   Scanning Head  |    YCG-S Series  |  
|   Voltage  |    |  
|   Test voltage output(Phase-Neutral)  |    3* (24V~288V)(or customized)  |  
|   Power of the voltage output  |    Max. 3x500VA  |  
|   Resolution  |    Better than 0.01% of full scale value of range  |  
|   Setting accuracy  |    Better than 0.05% at the final range value  |  
|   Stability  |    Better than 0.005% /h (integration time 150s)  |  
|   Load regulation from 0~max. load  |    Better than 0.01%  |  
|   Distortion factor  |    Better than 0.3% for linear resistance load  |  
|   Harmonic  |    2nd~21st free programmable  |  
|   Current  |    |  
|   Test current output  |    3* (1mA - 100A)  |  
|   Power of the current output  |    Max. 3x750VA  |  
|   Resolution  |    Better than 0.01% of full scale value of range  |  
|   Setting accuracy  |    Better than 0.05% at the final range value  |  
|   Stability  |    Better than 0.005% /h (integration time 150s)  |  
|   Load regulation from 0~max. load  |    Better than 0.01%  |  
|   Distortion factor  |    Better than 0.3% for linear resistance load  |  
|   Harmonic  |    2nd~21st free programmable  |  
|   Phase angle  |    |  
|   Range  |    0~360⁰  |  
|   Resolution  |    0.01⁰  |  
|   Setting accuracy  |    0.1⁰  |  
|   Frequency  |    |  
|   Range  |    45Hz~65Hz  |  
|   Resolution  |    0.01Hz  |  
|   Error display  |    |  
|   Type of error display  |    Red LED  |  
|   Resolution of error displays  |    8 digitals  |  
|   Other  |    |  
|   Voltage supply  |    3x220/380V±10%(or customized) 50/60Hz ±2Hz  |  
|   Ambient temperature  |    -10°C~+40°C  |  
|   Relative humidity  |    35%~85%  |  



For more information about our products, please refer to the following URL:http://www.genymetertestequipment.com/