Guangzhou GENY Electric Co., Ltd. is a leading energy meter test bench manufacturer with more than 30 years of industry experience. As the first company in China to export energy meter test benches, GENY has supplied high-precision testing equipment to customers in over 37 countries worldwide.
Our test bench is designed and manufactured in strict compliance with IEC 60736, ensuring exceptional accuracy, reliability, and long-term performance. It supports a wide range of electricity meter calibration requirements for both current applications and future testing standards.
Additionally, Guangzhou GENY Electric Co., Ltd. offers professional OEM and ODM services, allowing customers to customize energy meter test benches according to their specific technical needs, branding preferences, and application environments.
| Technical spec. | YC1893D-24 | |||
| Number of meter positions | 24 | |||
| Accuracy | 0.05 / 0.02 | |||
| Power Source | YCS-103-1200 | |||
| Standard Meter | SZ03A-K6 / SZ03A-K8 | |||
| Scanning Head | YCG-S Series | |||
| Voltage | ||||
| Test voltage output(Phase-Neutral) | 3x(24V~288V)(or customized) | |||
| Power of the voltage output | Max. 3x500VA | |||
| Resolution | Better than 0.01% of full scale value of range | |||
| Setting accuracy | Better than 0.05% at the final range value | |||
| Stability | Better than 0.005% /h (integration time 150s) | |||
| Load regulation from 0~max. load | Better than 0.01% | |||
| Distortion factor | Better than 0.3% for linear resistance load | |||
| Harmonic | 2nd~21st free programmable | |||
| Current | ||||
| Test current output | 3x(1mA~100A) | |||
| Power of the current output | Max. 3x750VA | |||
| Resolution | Better than 0.01% of full scale value of range | |||
| Setting accuracy | Better than 0.05% at the final range value | |||
| Stability | Better than 0.005% /h (integration time 150s) | |||
| Load regulation from 0~max. load | Better than 0.01% | |||
| Distortion factor | Better than 0.3% for linear resistance load | |||
| Harmonic | 2nd~21st free programmable | |||
| Phase angle | ||||
| Range | 0~360⁰ | |||
| Resolution | 0.01⁰ | |||
| Setting accuracy | 0.1⁰ | |||
| Frequency | ||||
| Range | 45Hz~65Hz | |||
| Resolution | 0.01Hz | |||
| Error display | ||||
| Type of error display | Red LED | |||
| Resolution of error displays | 8 digitals | |||
| Other | ||||
| Voltage supply | 3x220/380V±10%(or customized) | |||
| 50/60Hz ±2Hz | ||||
| Ambient temperature | -10°C~+40°C | |||