Guangzhou GENY Electric Co., Ltd. presents the YC-1893D Meter Test Bench, a high-precision energy meter testing system designed for three-phase mechanical and electronic electricity meters.
Complies with IEC 60736, providing accurate, stable, and long-lasting performance even in harsh environments.
Clear LED display for error readings
Wide current range for different meter types
Automatic or manual color mark positioning
Multi-position scanning head for fast testing
Quick and simple wiring
Works with mechanical and electronic meters
Stable power source ensures accurate results
Supports RS-232 / RS-485 interfaces and PC or manual control
| Technical spec. | YC1893D-6 | YC1893D-12 | YC1893D-24 | YC1893D-48 |
| Number of meter positions | 6 | 12 | 24 | 48 |
| Accuracy | 0.05 / 0.02 | |||
| Power Source | YCS-103-250 | YCS-103-600 | YCS-103-1200 | YCS-103-2500 |
| Standard Meter | SZ03A-K6 / SZ03A-K8 | |||
| Scanning Head | YCG-S Series | |||
| Voltage | | |||
| Test voltage output(Phase-Neutral) | 3x(24V~288V)(or customized) | |||
| Power of the voltage output | Max. 3x100VA | Max. 3x250VA | Max. 3x500VA | Max. 3x1000VA |
| Resolution | Better than 0.01% of full scale value of range | |||
| Setting accuracy | Better than 0.05% at the final range value | |||
| Stability | Better than 0.005% /h (integration time 150s) | |||
| Load regulation from 0~max. load | Better than 0.01% | |||
| Distortion factor | Better than 0.3% for linear resistance load | |||
| Harmonic | 2nd~21st free programmable | |||
| Current | | |||
| Test current output | 3x(1mA~100A) | |||
| Power of the current output | Max. 3x150VA | Max. 3x350VA | Max. 3x750VA | Max. 3x1500VA |
| Resolution | Better than 0.01% of full scale value of range | |||
| Setting accuracy | Better than 0.05% at the final range value | |||
| Stability | Better than 0.005% /h (integration time 150s) | |||
| Load regulation from 0~max. load | Better than 0.01% | |||
| Distortion factor | Better than 0.3% for linear resistance load | |||
| Harmonic | 2nd~21st free programmable | |||
| Phase angle | | |||
| Range | 0~360⁰ | |||
| Resolution | 0.01⁰ | |||
| Setting accuracy | 0.1⁰ | |||
| Frequency | | |||
| Range | 45Hz~65Hz | |||
| Resolution | 0.01Hz | |||
| Error display | | |||
| Type of error display | Red LED | |||
| Resolution of error displays | 8 digitals | |||
| Other | | |||
| Voltage supply | 3x220/380V±10%(or customized) 50/60Hz ±2Hz | |||
| Ambient temperature | -10°C~+40°C | |||
| Relative humidity | 35%~85% | |||