Yc1893D-12 Three Phase Meter Test System for Digital Display and Direct Installation
Specifications
| Technical spec. | YC1893D-ICT-6 | YC1893D-ICT-12 | YC1893D-ICT-24 | YC1893D-ICT-48 |
| Number of meter positions equipped ICT | 6 | 12 | 24 | 48 |
| Accuracy class of ICT | 0.05 / 0.01 |
| Accuracy | 0.05 |
| Power Source | YCS-103-250 | YCS-103-600 | YCS-103-1200 | YCS-103-2500 |
| Standard Meter | SZ03A-K6 / SZ03A-K8 (customized) |
| Scanning Head | YCG-S Series |
| Voltage | |
| Test voltage output(Phase-Neutral) | 3x(24V~288V)(or customized) |
| Power of the voltage output | Max. 3x100VA | Max. 3x250VA | Max. 3x500VA | Max. 3x1000VA |
| Resolution | Better than 0.01% of full scale value of range |
| Setting accuracy | Better than 0.05% at the final range value |
| Stability | Better than 0.005% /h (integration time 150s) |
| Load regulation from 0~max. load | Better than 0.01% |
| Distortion factor | Better than 0.3% for linear resistance load |
| Harmonic | 2nd~21st free programmable |
| Current | |
| Test current output | 3x(1mA~100A) |
| Power of the current output | Max. 3x150VA | Max. 3x350VA | Max. 3x750VA | Max. 3x1500VA |
| Resolution | Better than 0.01% of full scale value of range |
| Setting accuracy | Better than 0.05% at the final range value |
| Stability | Better than 0.005% /h (integration time 150s) |
| Load regulation from 0~max. load | Better than 0.01% |
| Distortion factor | Better than 0.3% for linear resistance load |
| Harmonic | 2nd~21st free programmable |
| Phase angle | |
| Range | 0~360⁰ |
| Resolution | 0.01⁰ |
| Setting accuracy | 0.1⁰ |
| Frequency | |
| Range | 45Hz~65Hz |
| Resolution | 0.01Hz |
| Error display | |
| Type of error display | Red LED |
| Resolution of error displays | 8 digitals |
| Other | |
| Voltage supply | 3x220/380V±10%(or customized) 50/60Hz ±2Hz |
| Ambient temperature | -10°C~+40°C |
| Relative humidity | 35%~85% |
Description
- Installing the ICT in each meter position to test three-phase meters with closed links between the current and voltage measuring circuits(I-P links)
- The meter test system can measure mechanical meter, electronic mechanical meters and electronic meter by ways of automatic, semi-automatic or manual operation.
- Meters under testing: 3P4W, 3P3W, 1P2W
- Testing mode: active power, reactive power, cross connected reactive power
- Simultaneously measure meters with same specifications but different meter constants
- Automatic positioning rotor mark of disc of mechanical meter, with more efficiency.
- Starting test and creeping test
- With the protection function of overload, short voltage circuit and open current circuit.
- The swing together of the scanning heads simplifies the control.
- Aluminum alloy material, light and strong and corrosion resistant
- The testing software with friendly Windows 2000 /XP /7 /8 /10 operation system, includes functional module of all kinds of modern energy meter needed, to reality error test, harmonic test, demand test, influence test etc,.
Applications
- Nation-level utility companies
- Governmental bureaus of metrology
- Big energy meter manufacturers
Primary Competitive Advantages
- High quality product
- Over 18 months long warranty
- High accuracy class: 0.05
- 3~48 Three Phase Electric Energy Meter Test bench
- Extremely high power stability
- Timing error test
- Influence test of voltage, frequency, and harmonic
- Installing RS232, Ethernet communication port in each meter position.
- Tilt impact test (optional)