Parking Lot Use, Transparent ON/OFF Motion Sensor
Remote and bottom DIP switch available for flexible configuration
Product Features
- Patented coupling dipole antenna design and Adaptive Algorithm effectively solves low installation height issues and false triggering from side-lobe radiation in metal rooms
- Ideal for parking lots and similar applications, overcoming traditional sensor limitations in vehicle detection
- Easy configuration via remote control and DIP switches for sensor parameter settings
Technical Parameters
| Input |
| Rated Voltage |
220-240Vac 50/60Hz |
| Stand-by Power |
≤0.5W |
| Surge Test |
1KV(L/N,EN61000-4-5) |
| Output |
| Output Signal |
ON/OFF |
| Type of Load |
Inductive or Resistive |
| Load Capacity |
200W@230Vac(Inductive); 400W@230Vac(Resistive) |
| Max. Surge Capacity |
7A relay 20A(50% Ipeak, twidth =200uS, 230Vac full load, cold start) |
| Sensor Parameters |
| Working Frequency |
5.8 GHz ±75MHz, ISM wave band |
| Transmitting Power |
1mW Max. |
| Detection Area (Radius) |
Ceiling mounting height 3m: r≥4m@0.3m/s, r≥2.5m@1m/s; Wall mounting height 3m: r≥5m@0.3m/s, r≥4m@1m/s (Test condition: Set 100% sensitivity, open 60㎡ indoor area) |
| Mounting Height |
3m (6m Max) |
| Hold Time |
5s/30s/90s/5min/20min/30min (Dial code) 5s/30s/1min/3min/5min/10min/20min/30min (MH10 setup) |
| Detection Area |
100%/75%/50%/25% |
| Daylight Sensor |
Normal Daylight: 2Lux/10Lux/30Lux/50Lux/Disable 5Lux/15Lux/30Lux/50Lux/100Lux/150Lux/Disable (MH10 setup) |
| Operating Temperature |
-25℃…+60℃ |
| Storage Temperature |
-40~80℃ Humidity: ≤85% non-condensing |
| Certificate Standards |
| Certified |
CE, RED |
| Environmental Requirements |
Comply with RoHS 2.0 Reach |
| IP Rating |
IP20 |
| Other |
| Remote Model |
MH10; MH16; MH03 |
| Wiring |
Press-in Type Terminals, wire diameter: 0.5-0.75mm² |
| Installation |
Built-in |
| Package |
Bubble bag+Clapboard + Carton(K=A) |
| Net Weight |
40.3±3g |
| Lifetime |
5 years warranty@Ta |
Function Overview
| Function |
Description |
| ON/OFF Function |
Light control disabled or external brightness lower than set value. When microwave sensor detects object movement, triggers light-on state. Maintains light-on state after delay, then enters light-off state. |
| Two-step Dimming Function |
N/A |
| Three-step Dimming Function |
N/A |
| Daylight Harvesting |
N/A |
| Daylight Priority |
N/A |
DIP Switch Settings
| Dial Code |
Daylight Sensor |
Hold Time |
Detection Area |
| Ⅰ |
2Lux |
5S |
100% |
| Ⅱ |
10Lux |
30S |
75% |
| Ⅲ |
30Lux |
90S |
50% |
| Ⅳ |
50Lux |
5min |
25% |
| Ⅴ |
Disable |
20min |
N/A |
| Ⅵ |
N/A |
30min |
N/A |
Radiation Pattern
MH10 Remote Control
Compatible remote control for sensor parameter configuration
Initialization
The light will be turned on at 100% brightness after power on, and will be turned off after 10 seconds. During initialization, no external motion sensing signals will be detected.
Default Settings
Sensitivity: 100% | Hold time: 5s | Daylight sensor: Disable
Application Notice
- Sensor should be installed by a professional electrician. Turn off power before installing, wiring, or changing DIP switch settings
- Sensitivity area relates to moving speed of objects, object size, mounting height, mounting angle, working environment, and reflecting materials. Given detection area is typical value measured by 165cm/65kg testers in indoor open environment
- Detection area increases significantly when installed on walls compared to ceiling mounting. For wall ceiling installation, reduce sensitivity or contact manufacturer for usage settings
- Daylight thresholds measured on sunny days without shadow in ambient light diffuse reflection. Different environments and climates affect measured brightness values
- Sensor parameters may need reconfiguration in different installation environments - refer to instructions or contact manufacturer
- For indoor use only. Outdoor or half-outdoor use affects waterproof performance. Wind, rain, and moving objects may cause false triggering
- Installation height cannot exceed 6 meters (optimal height: 3 meters). Distance between two sensors should be greater than 3m
- When installed in metal lamps, on metal reflective surfaces, or in small closed environments, microwave reflection may cause false triggering. Reduce sensitivity or contact manufacturer for technical support
- Ensure no moving signals (fans, DC motors, sewer pipes, air outlets, etc.) around sensor to prevent false triggering
- Microwaves cannot penetrate metal. Do not place product in closed or half-closed metal lamps. Metal or glass covering above product is not permitted