Technology parameters of Nutrition Pump

| Main features: |
| Reliable and Safe: |
| 1, Additional set of bubble alarm design(double bubble alarm) ensure more secure infusion; |
| 2, Advanced safety design able to stop infusion and alarm even if the CPU damage,the medical staff can ues it safely; |
| multipurpose: |
| Continuous feeding mode, Intermittent feeding mode. |
| Reduce the treatment costs: |
| Using common IV-set, No specific nutrient tube is required. |
| Pumping way: |
| Semi-squeeze finger-type peristaltic pump |
| IV-sets |
| Special or quality PVC/TPE infusion sets with an external diameter of 3.4mm~4.5mm |
| Feeding modes |
| 4 Feeding modes: |
| 1, Flow-rate: ml/h; |
| 2, Time-amount: ml/h; |
| 3, Drop-rate: d/min; |
| 4, Intermittent feeding mode. |

| Parameter range |
| 1, Flow-rate: 1.0~1200.0 ml/h, 0.1ml/h step; |
| 2, Time: 1s~99h59m59s, 1s step; |
| 3, Drop-rate: 1~333 d/min, 1 d/min step. |
| Precision |
| Better than ±5% (using a calibrated or a special IV-set) |
| Alarm |
| 1, Air in tube, 5 grades of sensitivity; |
| 2, Bubble sensor fault; |
| 3.1, Upper-end occlusion, -20~ -60 kPa,8 grades of sensitivity; |
| 3.2, Upper-end base-pressure fault; |
| 4.1, Lower-end occlusion, 20~ 140 kPa,8 grades of sensitivity; |
| 4.2, Lower-end base-pressure fault; |
| 5.1, Pump rotation fault; |
| 5.2, Inverse-infusion; |
| 6, Abnormal door-opening; |
| 7, Low battery power, battery fault; |
| 8, Overtime pause; |
| 9, Completed infusion; |
| 10, AC power fault; |
| 11, MCU fault, and stop infusion; |
| 12, Battery temperature is too high. |

Data function
1, Memory of calibration: Records the calibration data of tube automatically for application;
2, Memory of parameter: Records the latest feeding parameter for next operation;
3, Historical records: records latest 1000 feeding events.
(what/when/why,flow-rate, etc.)