ECG: | Baseline Recovery< 3 s After defibrillation. | Neonatal / Pediatric:0 ~ 150 BrPM | MEAN:20 ~ 110 mmHg | Measure and Alarm Range:0 ~ 50 ℃ |
Lead mode:5 Leads (I, II, III, AVR, AVL,AVF, V) | ECG Signal Range: ±5 mV (Vp-p) | Resolution:1 BrPM | Staticpressure accuracy: ±3mmHg | Resolution:0.1℃ |
| Bandwidth: | Accuracy:0~6 BrPM: unspecified | Resolution:1mmHg | Accuracy(no sensor):± 0.1℃(25℃ – |
Gain: 2.5mm/mV, 5.0mm/mV,10mm/mV, 20mm/mV | Surgery: 1 ~ 20 Hz | 7~150 BrPM: ±2 BrPM or ±2%, use the greater | Accuracy:MaximumMean | 45℃) ,± 0.2℃(other) |
| Monitor: 0.5 ~ 40 Hz | Inspiriting current:< 300 μA RMS max | Error:±5mmHg | Accuracy(include sensor):± |
Heart Rate:Measure range:Adult:15 ~ 300 bpm | Diagnostic: 0.05 ~ 130 Hz | Apnea Alarm:10 ~ 40 s | Maximum Standard Deviation:8mmHg | 0.2℃(32℃ - 42℃) ± 0.3℃(other) |
Neonatal/Pediatric: 15 ~ 350 bpm | Calibration Signal:1 mV p-p, ± 5% accuracy | NIBP: | Overpressure Protection:Adult:300 mmHg | PR: |
Accuracy: 1% | ST measurement: Range:-2.0 ~ +2.0 mV | Method:Oscillometry | Pediatric:240 mmHg | Measurement range:25 to 240 bpm |
Resolution:1 bpm | Accuracy:-0.8mV~+0.8mV: ±0.02mV or ±10%, which is greater | Measure Mode:Manual, Auto, STAT | Neonatal:150 mmHg | Resolution:1 bpm |
Sensitivity> 200 μV P-P | Other Range: unspecified | Measure Interval in AUTO | SpO2: | Accuracy:±3 bpm (measured without motion) |
Differential Input Impedance> 5 MΩ CMRR | Arrhythmia:13 Types: ASYSTOLE, VFIB/VTAC, COUTPLET, BIGMINY TRIGEMINY, R ON T, VT >2, BRADY, MISSED BEATS, PNP, PNC | Mode:1,2,3,4,5,10,15,30,60,90,120,180,240,480 min | Measurement Range:0 ~ 100 % | PR accuracy:±3 bpm |
Diagnostic Mode>90 dB | RESP: | Measure Period in STAT Mode:5 min | Resolution:1 % | ±5 bpm (measured with motion) |
Monitor Mode>110 dB | Method:Impedance between RA-LL or RA LA | Pulse Rate Range:40 ~ 240 bpm | Accuracy:70% ~ 100% ±2 % | Refreshing rate:1 s |
Surgery Mode>110 dB | Differential Input Impedance>2.5 MΩ | Measure and Alarm Range:Adult Mode | 0% ~ 69%:unspecified | Updated period:8 s, 16 s |
Offset Potential: ±300mV Leakage | Respiration Impedance Range:0.3~3Ω | SYS:40 ~ 280 mmHg DIA:10 ~ 220 mmHg | Pulse RateMeasure and Alarm | Low Perfusion: Conditions:Pulse |
Leakage Current< 10 μA | Base Impedance Range:200Ω-2000Ω | MEAN:20 ~ 240 mmHg | Range:20~250bpm | amplitude: >0.02% |
Pace Pulse Detect: Range:±2~±700mV | Bandwidth:0.3 ~ 2 Hz | Pediatric Mode: SYS:40 ~ 220 mmHg | Resolution:1bpm | Light penetration: >5% |
Width:0.1~2ms Rise Time:10~100μs | Gain:x0.5,x1,x2,x4 | DIA:10 ~ 160 mmHg MEAN:20 ~ 170 mmHg | Accuracy:±3bpm | SpO2 accuracy:±2% |
Pace Pulse Rejection: Range:±2~±700mV | Respiration Rate: Measurement Range: | Neonatal Mode:SYS:35 ~ 135 mmHg | TEMP: | |
Width:0.1~2ms Rise Time:10~100μs | Adult:0 ~ 120 BrPM | DIA:10 ~ 100 mmHg | Channel:2 | |