Grundfos GLF-G4-12mm 4R Stainless Steel Vertical Multi-Stage Pump Mechanical Seal with Flange Plate
SUS304 Single Spring Mechanical Seal for Grundfos GLF-G4-12mm pumps, suitable for 1/3/5 ton water systems.
Technical Parameters
| Parameter |
Specification |
| Temperature |
-30℃ to +200℃ |
| Pressure |
≤1.2 MPa |
| Speed |
≤10 m/s |
| Medium |
Acid, alkali, and corrosive liquids |
Material Composition
| Component |
Material |
| Rotary Ring |
SiC/VIT |
| Stationary Ring |
Carbon/SiC/TC |
| Spring |
SUS304/SUS316 |
| Stationary Seat |
SUS304/SUS316 |
| Secondary Seal |
FKM |
| Rotary Ring Holder |
SUS304/SUS316 |
Installation Preparation
- Shaft outside diameter tolerance: ±0.05mm
- Shaft run out: <0.1mm
- Shaft end float: <0.13mm
- No sharp edges on the shaft over the O-ring
Note: During installation, avoid scratching or damaging the O-ring. If any damage occurs, contact us for replacement.
Installation Instructions
The complete cartridge seal set is cleaned and leak-tested before sale. Do not disassemble and clean parts again before installation to avoid damage.
- Shaft fitting allowance: dl h6 0.8 with leading edge at shaft end
- Shaft diameter at screw position should be 0.1-0.2mm smaller to prevent over-tightening
- Lubricate shaft with oil before installation
- Place cartridge seal into pump chamber, then:
- Tighten four flange screw bolts, ensuring medium leading hole "G" is at top position
- Tighten four set screws to position shaft sleeve on shaft
- Remove four gauge plates (keep for future installation/disassembly)
- Connect medium lead-in pipe with hole "G" to flush away friction heat and seal chamber during pump operation
Note: After installation, turn shaft by hand to check rotation. If shaft doesn't rotate smoothly, seal was improperly installed.
We are committed to providing high-quality products and services, and believe in establishing long-term cooperative relationships for mutual success.