LV Low Voltage Switchgear is used as indoor power distribution equipment for ring network and terminal power supply in factories, workshops, residential districts, high-rise buildings, schools, parks and other places.
 2. KYN28-12 Metal-enclosed Electrical High Voltage Switchgear Cubicle 
  
|  			 Project  			 |  			 			 Unit  			 |  			 			 Data  			 |  		||||||
|  			 Rated voltage  			 |  			 			 kV  			 |  			 			 3.6  			 |  			 			 7.2  			 |  			 			 12  			 |  		||||
|  			 Rated frequency  			 |  			 			 Hz  			 |  			 			 50  			 |  			 			 60  			 |  			 			 -  			 |  			 			 -  			 |  			 			 -  			 |  			 			 -  			 |  		|
|  			 Rated current of circuit breaker  			 |  			 			 A  			 |  			 			 630  			 |  			 			 1250  			 |  			 			 1600  			 |  			 			 2000  			 |  			 			 2500  			 |  			 			 3150  			 |  		|
|  			 Rated current of switchgear  			 |  			 			 A  			 |  			 			 630  			 |  			 			 1250  			 |  			 			 1600  			 |  			 			 2000  			 |  			 			 2500  			 |  			 			 3150  			 |  		|
|  			 Rated short time withstand current(4s)  			 |  			 			 kA  			 |  			 			 16  			 |  			 			 20  			 |  			 			 25  			 |  			 			 31.5  			 |  			 			 40  			 |  			 			 50  			 |  		|
|  			 Rated peak withstand current  			 |  			 			 kA  			 |  			 			 40  			 |  			 			 50  			 |  			 			 63  			 |  			 			 80  			 |  			 			 100  			 |  			 			 125  			 |  		|
|  			 Rated short circuit breaking current  			 |  			 			 kA  			 |  			 			 16  			 |  			 			 20  			 |  			 			 25  			 |  			 			 31.6  			 |  			 			 40  			 |  			 			 50  			 |  		|
|  			 Rated short circuit closing current  			 |  			 			 kA  			 |  			 			 40  			 |  			 			 50  			 |  			 			 63  			 |  			 			 80  			 |  			 			 100  			 |  			 			 125  			 |  		|
|  			 Rated insulation level  			 |  			 			 1min power frequency withstand voltage  			 |  			 			 kV  			 |  			 			 24  			 |  			 			 32  			 |  			 			 42  			 |  		|||
|  			 Lingtning impulse withstand coltage  			 |  			 			 kV  			 |  			 			 40  			 |  			 			 60  			 |  			 			 75  			 |  		||||
|  			 Protection grade  			 |  			 			 Shell is IP4X, IP2X when circuit breaker door is open  			 |  		|||||||
 
 3. Photo
 
 
 4. Factory
 
  
 5. Delivery
 
  
 6. FAQ
 1. Send the technical data, better for all useful information; we will make a good recommendation.
 If possible please attach one reference picture to avoid any misunderstanding or any links from our website for we get a better understanding.
 2. The lead time depend on quantity of order. Some standard type is on stock. Otherwise, it will take 3-15 days.
 3. Usually shipped by sea, small order or urgent order we can send you by air.
 4. All our activities are accredited to ISO 14001:2015 and IEC standard.
 5. Technology ensure the quality satisfy international request.