European style container type Prefab House For School Construction
Technical Parameter of standard prefabricated house
1. Wind resistance: Grade 11(wind speed≤111.5km/h)
2. Earthquake resistance: Grade 7
3. Live load capacity of roofing: 0.5kn/m2
3. External and internal wall heat transmission coefficient: 0.35Kcal/m2hc
4. First floor load capacity: 150 kg/m2
5. Live load of corridor is 2.0kn/ m2
| Steel Structure |
| 1.1 | Steel column | 120x120x2.5 | |
| 1.2 | Steel structure beam | C120x50x20x2.0 | |
| 1.3 | Roofing Purlin | C140x50x20x2.0 | |
| Steel Structure |
| 1.4 | Wall Purlin | C120x50x20x2.0 | |
| 1.5 | Anchor Bolts | M16 | |
| 1.6 | Ordinary Bolts | 4.8S, Galvanized | |
| Roof and Wall |
| 2.1 | Roofing-PU board Or Fiber glass board or EPS panel | 100mm,40kg, 0.5/0.5mm, heather transfer≤0.021w/mk, anti press≥210Kpa; OR 100mm,60kg, 0.5/0.5mm, heat transfer≤0.028w/mk, anti press≥180Kpa |
| 2.2 | Ceiling upon the door | 100mm,40kg, 0.5/0.5mm, heather transfer≤0.021w/mk, anti press≥210Kpa; OR 100mm,60kg, 0.5/0.5mm, heat transfer≤0.028w/mk, anti press≥180Kpa |
| 2.3 | Exterior wall-PU board OR Rockwool board or EPS panel | 100mm,40kg, 0.5/0.5mm, heather transfer≤0.021w/mk, anti press≥210Kpa; OR 100mm,60kg, 0.5/0.5mm, heat |
| Ceiling and Ground |
| 3.1 | gypsum ceiling-for room | 600*600*6mm, including frame |
| 3.2 | PVC ceiling-for toilet | PVC Board |
| 3.3 | Flooring Tile | 600*600mm |
| Door and Window |
| 4.1 | Exterior Door | Light Steel Door |
| 4.2 | Interior Door | Sandwich Panel Door or Light Steel Door |
| 4.3 | Window | PVC, With double glass 4+6+4mm |
| Electric Cable |
| 5.1 | Electric Cable | lighting 2.5mmm2, air conditioner : 4.0mm2 |
| 5.2 | PVC Wire Channel | | |
| 5.3 | Light | | |
| 5.4 | Switches | With Junction Box | |
| 5.5 | Socket | 16A Universal Socket | |
| 5.6 | Water Heater | | |
| 5.7 | Power Distribution Cabinet | | |
| 5.8 | Bidet | | |
| 5.9 | Closestool | | |
| 5.10 | Washbasin | | |
| 5.11 | Shower | | |