GOMECY 10600nm 60W CO2 Fractional Laser Machine Professional Aesthetic Beauty Equipment with 15 Inch Touch Screen
The GMS-C6 Fractional CO2 Laser System is a multi-mode professional platform combining fractional scanning and precision laser operation in one system. It integrates a 10600nm CO2 laser source, high-speed scanner, articulated optical arm, touch control system and interchangeable treatment heads.
Operators can adjust laser power, scanning dimensions, point spacing, point duration and scanning mode according to different professional operating requirements. The system provides Fractional, Gynae, Pulsed/Cutting, Vulva and Cosmetology modes, allowing one platform to support a variety of professional aesthetic applications.

Quick Details
- Product Model: GMS-C6
- Technology: Fractional CO2 Laser
- Laser Wavelength: 10600nm
- Maximum Power: 60W
- Adjustable Power: 1-60W
- Fractional Scan Area: 1×1mm to 20×20mm
- Point Spacing / Density: 0.1-2.0mm
- Fractional Point Duration: 0-10ms
- Cutting Mode Pulse Width: 0.1-100ms
- Transmission System: 7-Joint Articulated Arm
- Scan Patterns: Square, Diamond, Circle, Linear, Hexagon, Triangle
- Scan Modes: Sequence, Half, Random
- Working Modes: Fractional, Gynae, Pulsed/Cutting, Vulva, Cosmetology
- Standard Heads: 1 Fractional Head + 1 Cutting Head + 3 Vaginal Heads
Main Uses
Designed for trained professional operators in aesthetic and beauty-care settings. Typical professional applications include:
- Fractional skin resurfacing
- Skin texture and appearance care
- Appearance care for acne-related marks and scars
- Fine-line and wrinkle care
- Skin rejuvenation procedures
- Fractional laser procedures
- Precision cutting applications
- Gynecological aesthetic applications
- Vulva aesthetic care
Core Specifications
- 10600nm CO2 Laser Technology: Professional CO2 laser platform with fractional scanning and pulsed laser operating capabilities.
- 1-60W Adjustable Output: Laser power can be adjusted in 1W steps according to the selected operating mode and professional application.
- Adjustable Fractional Scanner: X and Y scanning dimensions can each be adjusted from 1mm to 20mm.
- Adjustable Point Spacing: Point spacing can be set from 0.1mm to 2.0mm. Smaller spacing corresponds to higher dot density.
- Multiple Scan Patterns: Square, Diamond, Circle, Linear, Hexagon and Triangle patterns are available.
- Three Scan Modes: Sequence, Half and Random scanning modes provide flexible dot-distribution options.
Working Principle
The system uses a 10600nm CO2 laser combined with fractional scanning technology. In Fractional Mode, the scanner distributes laser energy into an arranged pattern of individual points across the selected scanning area, with controlled spacing between adjacent points.
The operator can adjust power, point duration, point spacing, scanning dimensions and scanning method through the control interface. Point energy is related to laser power and point duration; increasing point duration increases the energy delivered at each point under the same power setting.
For cutting applications, the system provides dedicated pulsed operating options with adjustable power and pulse width.
Working Modes
- Fractional Mode: Adjustable power, graphic size, point spacing/density, point duration, scan mode, scan times and interval settings.
- Pulsed / Cutting Mode: Power adjustable from 1-60W; pulse width adjustable from 0.1-100ms. The interface includes pulsed, super-pulsed, single and continuous selections as described in the manual.
- Gynae Mode: Dedicated parameter settings for use with compatible vaginal treatment heads.
- Vulva Mode: Supports adjustable power, graphic size, point duration, point density and scanning parameters.
- Cosmetology Mode: Provides six scanning patterns and adjustable fractional parameters for professional aesthetic applications.
Application Scenarios
- Beauty salons
- Aesthetic centers
- Skin management centers
- Professional beauty studios
- Cosmetic service centers
- Beauty equipment distributors
- Professional training and demonstration environments
Actual application and operating requirements should follow applicable local regulations, product labeling and professional operating guidelines.
Technical Parameters
| Parameter |
Specification |
| Product Model |
GMS-C6 |
| Laser Type |
CO2 Laser |
| Wavelength |
10600nm |
| Maximum Power |
60W |
| Adjustable Power |
1-60W, 1W step |
| Indication Beam |
Diode Laser, 532nm, 5mW |
| Transmission System |
7-Joint Articulated Arm |
| Scan Area |
1×1mm - 20×20mm |
| Scan Patterns |
Square, Diamond, Circle, Linear, Hexagon, Triangle |
| Scan Modes |
Sequence, Half, Random |
| Point Spacing / Density |
0.1-2.0mm |
| Fractional Point Duration |
0-10ms |
| Cutting Pulse Width |
0.1-100ms |
| Scan Depth |
2mm |
| Working Modes |
Fractional / Gynae / Pulsed-Cutting / Vulva / Cosmetology |
| Fractional Head |
1 pc |
| Cutting Head |
1 pc |
| Vaginal Heads |
3 pcs |
| Foot Switch |
1 pc |

Standard Configuration
- 1 × Fractional Head
- 1 × Cutting Head
- 3 × Vaginal Heads
- 1 × Foot Switch
- 1 × Goggles
- 1 × Protective Glass
- 1 × Power Cable Set
- 1 × User Manual
Competitive Advantages
- Fractional + Cutting in One Platform: Combines fractional scanning and dedicated cutting functions in one system.
- Wide Adjustable Power: 1-60W adjustable output provides flexibility for different working modes.
- Flexible Fractional Parameters: Scan size, point spacing, point duration, power and scanning mode can be adjusted.
- Six Scanning Patterns: Multiple graphic options help adapt the scan layout to different operating areas.
- Three Scanning Methods: Sequence, Half and Random modes provide flexible scanning options.
- Adjustable Scan Area: X and Y dimensions are adjustable from 1mm to 20mm.
- Multiple Professional Modes: Fractional, Gynae, Pulsed/Cutting, Vulva and Cosmetology modes are integrated.
- Complete Standard Configuration: Fractional, cutting and vaginal heads are included in the standard configuration.
Why Choose GMS-C6?
GMS-C6 focuses on parameter flexibility and multi-function integration. Instead of relying on fixed fractional settings, operators can independently control key parameters such as power, scan area, point spacing, point duration, scan pattern and scan mode. This provides greater flexibility for different professional operating preferences and application requirements.
Safety & Operation
The equipment should be operated by trained professionals who understand the operating procedures, parameter settings and relevant precautions. Appropriate laser protective eyewear should be used during operation, and the user manual should be read carefully before operating the equipment.
Fractional CO2 Laser, CO2 Laser Machine, 10600nm CO2 Laser, Fractional Laser System, CO2 Fractional Machine, Fractional Scanner, CO2 Laser Equipment, Beauty Equipment, Aesthetic Equipment, Professional Beauty Machine, Skin Care Equipment, Fractional Laser Machine, 60W CO2 Laser, Laser Beauty Equipment, Cutting Laser Machine, Fractional Beauty Equipment, Professional Aesthetic Equipment, Beauty Salon Equipment, GMS-C6