Humidity Testing Low And Empty Water Level Alarm Temperature Humidity Chamber
Temperature and humidity chamber.pdf
Download:Temperature and humidity chamber.pdf
Standard Features:
2. Specifications :
Range – 40 to 150°C
|   			 Temp/Humidity  |   			  			 HD-E702-100-4  |   			  			 HD-E702-150-4  |   			  			 HD-E702-225-4  |   		|
|   			 
  |   			  			 HD-E702-408-4  |   			  			 HD-E702-800-4  |   			  			 HD-E702-1000-4  |   		|
|   			 Temp-only  |   			  			 HD-E702-100T-4  |   			  			 HD-E702-150T-4  |   			  			 HD-E702-225T-4  |   		|
|   			 
  |   			  			 HD-E702-408T-4  |   			  			 HD-E702-800T-4  |   			  			 HD-E702-1000T-4  |   		|
|   			 Temperature Range:  |   			  			 -40°C ~150°C  |   		|||
|   			 Cooling Capacity  |   			  			 ~ 2 kW at -20°C  |   			  			 ~ 2.5 kW at -20°C  |   			  			 ~ 4.5 kW at -20°C  |   		|
|   			 ~ 5.5 kW at-20°C  |   			  			 ~ 8 kW at -20°C  |   			  			 ~ 8.5 kW at - -20°C  |   		||
|   			 Heating System  |   			  			 ~ 5 kW  |   			  			 ~ 5 kW  |   			  			 ~ 5.5 kW  |   		|
|   			 ~6.5 kW  |   			  			 ~ 8.5 kW  |   			  			 ~ 9 kW  |   		||
|   			 Temperature Fluctuation:  |   			  			 ±0.5°C  |   		|||
|   			 Temperature Gradient:  |   			  			 ±0.5°C~±0.2°C  |   		|||
|   			 Heating Rate†:  |   			  			 ≥3℃ / min average ( Advance model 5 – 15 ℃ / min)  |   		|||
|   			 Cooling Rate†:  |   			  			 ≥1℃ / min average (Advance model 5 - 15℃ / min)  |   		|||
|   			 Humidity Range:  |   			  			 10%~95%RH (Ref to Normal Humidity Range Diagramed)  |   		|||
|   			 Humidity Fluctuation:  |   			  			 ±1.5%RH~±2.0%RH  |   		|||
|   			 Humidity Gradient:  |   			  			 ±3%RH  |   		|||
|   			 Dimensions  |   		||||
|   			 Workspace dimensions  |   			  			 500x400x500 HD-E702-100  |   			  			 600x500x500 HD-E702-150  |   			  			 750x500x600 HD-E702-225  |   		|
|   			 
  |   			  			 850x650x800 HD-E702-800  |   			  			 1000x1000x800 HD-E702-800  |   			  			 1000x1000x1000 HD-E702-1000  |   		|
|   			 Exterior dimensions  |   			  			 1400x850x1050  |   			  			 1500x950x1050  |   			  			 1650x950x1150  |   		|
|   			 
  |   			  			 1750x1050x1350  |   			  			 1900x1450x1350  |   			  			 1900x1450x1550  |   		|
|   			 Site Requirements  |   		||||
|   			 Electrical Supply:  |   			  			 208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific)  |   		|||
|   			 Humidity Water  |   			  			 Distilled Water  |   		|||
|   			 Condensate Drain:  |   			  			 1/2" hose connection (gravity drain)  |   		|||
Range – 70 to 150°C
|   			 Temp/Humidity  |   			  			 HD-E702-100-7  |   			  			 HD-E702-150-7  |   			  			 HD-E702-225-7  |   		|
|   			 
  |   			  			 HD-E702-408-7  |   			  			 HD-E702-800-7  |   			  			 HD-E702-1000-7  |   		|
|   			 Temp-only  |   			  			 HD-E702-100T-7  |   			  			 HD-E702-150T-7  |   			  			 HD-E702-225T-7  |   		|
|   			 
  |   			  			 HD-E702-408T-7  |   			  			 HD-E702-800T-7  |   			  			 HD-E702-1000T-7  |   		|
|   			 Temperature Range:  |   			  			 -70°C ~150°C  |   		|||
|   			 Cooling Capacity  |   			  			 ~ 2.5 kW at -50°C  |   			  			 ~ 3 kW at -50°C  |   			  			 ~ 5 kW at -50°C  |   		|
|   			 ~ 6.5 kW at-50°C  |   			  			 ~ 8.5 kW at -50°C  |   			  			 ~ 9 kW at - -50°C  |   		||
|   			 Heating System  |   			  			 ~ 5 kW  |   			  			 ~ 5 kW  |   			  			 ~ 5.5 kW  |   		|
|   			 ~6.5 kW  |   			  			 ~ 8.5 kW  |   			  			 ~ 9 kW  |   		||
|   			 Temperature Fluctuation:  |   			  			 ±0.5°C  |   		|||
|   			 Temperature Gradient:  |   			  			 ±0.5°C~±0.2°C  |   		|||
|   			 Heating Rate†:  |   			  			 ≥3℃ / min average ( Advance model 5 – 15 ℃ / min)  |   		|||
|   			 Cooling Rate†:  |   			  			 ≥1℃ / min average (Advance model 5 - 15℃ / min)  |   		|||
|   			 Humidity Range:  |   			  			 10%~95%RH (Ref to Normal Humidity Range Diagramed)  |   		|||
|   			 Humidity Fluctuation:  |   			  			 ±1.5%RH~±2.0%RH  |   		|||
|   			 Humidity Gradient:  |   			  			 ±3%RH  |   		|||
|   			 Dimensions  |   		||||
|   			 Workspace dimensions  |   			  			 500x400x500 HD-E702-100  |   			  			 600x500x500 HD-E702-150  |   			  			 750x500x600 HD-E702-225  |   		|
|   			 
  |   			  			 850x650x800 HD-E702-800  |   			  			 1000x1000x800 HD-E702-800  |   			  			 1000x1000x1000 HD-E702-1000  |   		|
|   			 Exterior dimensions  |   			  			 1400x850x1050  |   			  			 1500x950x1050  |   			  			 1650x950x1150  |   		|
|   			 
  |   			  			 1750x1050x1350  |   			  			 1900x1450x1350  |   			  			 1900x1450x1550  |   		|
|   			 Site Requirements  |   		||||
|   			 Electrical Supply:  |   			  			 208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific)  |   		|||
|   			 Humidity Water  |   			  			 Distilled water  |   		|||
|   			 Condensate Drain:  |   			  			 1/2" hose connection (gravity drain)  |   		|||
3. Performance of Stability High Low Temperature and Humidity Test chamebr:
Get a performance evaluation to help provide the suitable chambers to you.
For better assurance of performance for your temperature and humidity cycling application, Haida can provide a guaranteed performance calculation based on your submitted requirements.
Please use these questions as below as a guide to define your test plan. You can then give this information to our lab consultant or email to us, for review by our lab consultant. A recommended model with appropriate refrigeration size will provide to you.
System & Performance Options

(Normal Humidity Range Diagramed)
4. view:

(Advanced refrigeration design is especially compact for HD-Series Chambers)