ASTM D525 Petroleum Testing Instruments SH8018 Automatic Gasoline Oxidation Stability Tester ( Induction Period Method
SH8018 Automatic gas oxidation stability is according to the law of the People's Republic of China standard GB/T 8018-87 "gasoline oxidation stability measurement method (induction period) the requirements stipulated in the design and manufacture, suitable for according to GB/T 8018 standard determination of accelerated oxidation under the condition of the oxidation stability of gasoline, equipped with color LCD screen, the screen can be real-time display of sample temperature, pressure curve, the user can set the stress of specimen, real-time time or modify the instrument.
Using the embedded system design, the user can view the historical data, using the instrument printer to print the results.
The instrument also conforms to ASTM D525 standard.
ASTM D525 Induction Period Method Automatic Gasoline Oxidation Stability Tester
Gasoline Test Kit Fully Automatic Oxidation Stability Analyzer ASTM D525
Induction Period Method Oxidation Stability Tester
Induction Period Method ASTM D525 Automatic Oxidation Stability Bath of Gasoline
Gasoline Oxidation Stability Tester with Induction Period Method
ASTM D525 Oxidation Stability Test Machine (Induction Period Method)
Main technical indexes and parameters
1, working power supply: AC220V± 5%, 50Hz.
2. Heating tube power: 1800W
3.Oxygen bomb pressure transmitter measuring range: (0 ~ 1600)kPa, accuracy: ±2‰.
4, water bath temperature control point: 100.0℃±0.1℃.
5, thermometer: equipped with glass mercury thermometer, can be adjusted at any time according to the need of the system.
6. Ambient temperature: ≤30℃.
7, relative humidity: ≤85%.
8.Boundary dimension: 660 * 400 * 350mm Weight: 40kg
Power supply | AC(220±5%)V,50Hz; |
Total power consumption | ≤1800W; |
Heating power | Less 1000W, the actual heating power is automatically controlled by computer |
Measuring range of oxygen bomb pressure transmitter | (0~1600)kPa, accuracy ±2‰ |
Temperature control point of water bath | 100±0.1℃. |
Thermometer | equipped with glass mercury thermometer, can be adjusted at any time according to the need of the system. |
Ambient temperature | ≤30℃. |
Relative humidity | ≤85% |
Boundary dimension: 660 * 400 * 350mm Weight: 40kg |
Packing list
S/N | Name | Unit | Quantity | Remarks |
1 | Host | set | 1 | |
2 | Test oxygen bomb assembly | set | 2 | |
3 | Special glass mercury thermometer for induction period | piece | 1 | |
4 | Glass test bottle and cap | set | 2 | |
5 | Instruction | copy | 1 | |
6 | Packing list | copy | 1 | |
7 | Certificate warranty card | copy | 1 |