HbA1c Analyzer Fully Automatic LD-560 Hemoglobin Detection Analyzer HPLC Method Support
Intended Use
- The Fully Automated HbA1c Analyzer is used in conjunction with suitable reagents for the quantitative detection of glycosylated hemoglobin (HbA1c) in human blood.
- This analyzer is a fully automated instrument used to analyze glycosylated hemoglobin. It has the characteristics of small sample amount and simple operation. It is suitable for the detection of glycosylated hemoglobin in medical institutions.
Specifications
| Brand | Labnovation |
| Name | FullY Automatic HbA1c Analyzer |
| Model | LD-560 |
| Method | HPLC |
| Parameters | HbA1c, HbF, HbA1a, HbA1b, HbA0; HbA2 (optional) |
| Test Speed | 90 seconds per test |
| Wavelength | 420nm |
| Sample Type | Whole Blood, Pre-diluted blood |
| Autoloader Capacity | 20 tubes |
| Precision | CV<2% |
| Column Capacity | 3000 tests |
| Working Condition | Temperature: 15-30℃ |
| Net weight | 28kg |
| Storage environment: Temperature | -20℃~55℃ |
| Humidity | 10%~93% |
| Equipment category | Fixed |
| Equipment type of tested product | Laboratory |
| Atmospheric pressure | 75kPa~106kPa |

Feature
- Simple Maintenance
- Full Modular Design
- Automatic washing channel
- Easy to change the chromatography column
Advantage
- Fully automated operation saves time and labor
- Automatic Primary tube sampling with cap puncture
- Auto identificate the whole blood or lyse
- Automatic Calibration, Can correspond to IFCC & NGSP, get reliable result.
- Built-in quality control management simplifies quality assurance compliance

Performance Parameters
-
Repeatability: For samples with a test concentration of 4%-6%, the sample coefficient of variation (CV) of the test results is not greater than 2.0%.
-
Linear range: Within the range of 3%-18% of glycosylated hemoglobin, the linear correlation coefficient R value of the test results should not be less than 0.9900.
-
Carrying pollution: The carrying pollution rate of the analyzer should not be greater than 2.0%.
-
Basic function: Provides Chinese report and abnormal alarm.
Other Information
- The analyzer is equipped with a USB interface and a network port. The USB interface is used for software upgrades by after-sales engineers, and the network port is used to transmit test data to the hospital LIS system.
-
- The system provides two different login accounts: engineer and ordinary user. You can log in by entering the corresponding user name and password. Only when you log in with an engineer account, you can read the U disk data through the USB connector to upgrade software. The USB type is Host (host device), and the internal data of the analyzer cannot be accessed through the connector.