HbA1c Test Analyzer HPLC Method Hemoglobin Test LD-560 Fully Automatic HbA1c Detection Analyzer
Intended Use
- The Fully Automated HbA1c Analyzer is used in conjunction with suitable reagents for the quantitative detection of glycosylated hemoglobin (HbA1c) in human blood.
- This analyzer is a fully automated instrument used to analyze glycosylated hemoglobin. It has the characteristics of small sample amount and simple operation. It is suitable for the detection of glycosylated hemoglobin in medical institutions.
- The analyzer consists of an auto sample injection module, a liquid chromatography separation module, a colorimetric detection and control module, a barcode scanning module, and a display printing module.
Specifications
| Name | Fully Automated HbA1c Analyzer |
| Model | LD-560 |
| Method | HPLC(High Performance Liquid Chromatography) |
| Parameters | HbA1c, HbF, HbA1a, HbA1b, HbA0; HbA2 (optional) |
| Test Speed | 90 seconds per test |
| Wavelength | 420nm |
| Sample Type | Whole Blood, Pre-diluted blood |
| Autoloader Capacity | 20 tubes |
| Precision | CV<2% |
| Column Capacity | 3000 tests |
| Working Condition | Temperature: 15-30℃ |
| Net weight | 28kg |
| Storage environment: Temperature | -20℃~55℃ |
| Humidity | 10%~93% |

Principle
- Using high performance liquid chromatography (HPLC), the stationary phase used is a weakly acidic cation exchanger.
- Glycosylation of hemoglobin will result in the loss of cations on the surface of hemoglobin without being charged, and non-glycosylated hemoglobin has a positive charge.
- Each component is detected by a single-wavelength colorimeter, and the detected data is processed by a computer to calculate the percentage content of HbA1c in the total hemoglobin.
Feature
- No Sample Pre-treatment
- Fully automated operation saves time and labor
- Automatic Primary tube sampling with cap puncture
- Auto identificate the whole blood or lyse
- Batch sampling offer flexibility in workflow
Advantage
- HPLC Method
- Support barcode scanner
- Built-in thermal printer, support auto print
- Proven golden standard method for HbA1c testing
- Certificated by NGSP, IFCC and ISO9001

Performance Parameters
-
Reporting unit: Glycosylated hemoglobin (HbA1c) is reported in NGSP (%) and IFCC units (mmol/mol).
-
Accuracy: The accuracy is tested with reference materials as samples, and the relative deviation of the test results should be within ±5%.
-
Stability Within 8 hours after the analyzer is turned on and stabilized, the same normal sample is tested, and the relative deviation of the test results is not more than ±3.0%.
-
Carrying pollution: The carrying pollution rate of the analyzer should not be greater than 2.0%.
FAQ
- What's your product lead time?
Normally all our medical equipment are in stock, so we can deliver goods within 5 workdays after receipt payment.
- How to maintenance the product if it has problem?
We have professional engineers,they will solve your problem by communicating with skype or phone.
- What about the price level?
Our prices are competitive compared with those at the same quality level, and we keep striving to provide the best pricing to our customers.
Certificated