Computer-Controlled Fire Extinguisher Hydrostatic Pressure Test System
Overview
The piping system uses non-welded connections with separate test fluid and drive fluid systems, allowing for various test media. Three control methods are available: manual control, PLC control, and computer control. High-speed sampling cards collect test data, while computer-controlled servo motors manage high-pressure inflation and pressure control.
Equipment Features
- Imported electric plunger booster pump for easily adjustable and controllable output pressure
- Advanced technology with compact, lightweight design and elegant appearance
- Pressure-bearing parts use international brand standard parts with no welded connections for easy disassembly, safety, and maintenance
- 220V driving power supply with 2.2kw total power
- Computer-controlled rate-controlled pressurization
- Pressure test range: 0-6Mpa (selected according to customer requirements)
- Real-time pressure curve display and test report printing capability
- Pressure compensation for high-pressure end pressure loss
- Real-time pressure curve output and collection for entire pressurization process
- Set pressure stop function with servo-controlled pressurization rate for accurate testing
Technical Specifications
| Test Medium |
Clean Water |
| Test Pressure |
0-6 MPa |
| Pressurization Flow Rate |
8 L/min (servo closed-loop system) |
| Time Display |
Computer Display |
| Pressure Curve Display |
Real-time display with zoom-in/out functionality via data acquisition software |
| Report Printing |
Test reports can be printed and test data saved upon completion |
| Test Data Saving |
Reports and Excel test tables can be saved; all collected data can be stored |
| Display Accuracy |
0.01 MPa |
| Control Accuracy |
±0.1 MPa |
| Acquisition Accuracy |
0.5% FS |