Battery Recovery Discharge Testing Machine Single Cell Recovery Discharge Equipment Recycling Discharge Device
This advanced battery recovery discharge testing machine is designed for efficient discharge processes during lithium-ion battery recycling operations. The equipment features customizable configurations and intelligent discharge management for optimal performance.
Specifications and Components
- Each unit consists of customizable main channels (quantity adjustable per requirements)
- Complete set includes discharge main channels, battery racks, connection lines, and clamps
- Versatile crocodile clip battery clamps compatible with both cylindrical and pouch batteries
Equipment Features and Capabilities
Application Scope
Primarily designed for discharge processes in single lithium-ion battery recycling operations.
Key Functions
- Parallel Discharge: Each main channel supports simultaneous connection of 20 batteries with independent operation
- Safety Protection: Optimized circuit design prevents short circuits, reverse connections, and uncontrolled discharge
- Intelligent Equalization: Automatic adjustment of discharge current based on battery voltage (up to 20A)
- Voltage Monitoring: Real-time collection and comparison of battery voltages with dynamic display of highest/lowest values
- PC Integration: Full equipment control via upper computer software with detailed voltage monitoring
- Safety Checks: Automatic battery presence detection (0.5V threshold) with alarm system for contact faults
- Data Recording: Automatic generation of termination data when batteries reach set voltage thresholds
Technical Specifications
| Parameter |
Specification |
| Main channels per cabinet |
Customizable quantity |
| Auxiliary channels per main channel |
20 units |
| Energy consumption |
Discharge energy converted to heat via electronic load |
| Working modes |
Constant current, constant power, constant resistance, multi-stage, cyclic discharge |
| Stage termination conditions |
Time, quantity of cells, ampere-hour |
| Real-time display |
Current, cell voltage, time, stage, mode, Ah, Wh |
| Time resolution |
1 second |
| Timing accuracy |
±10 seconds/24 hours |
| Stage time range |
1 second - 1000 hours |
| Stage setting range |
1-200 stages |
| Discharge voltage range |
Customizable (minimum 1.5V per battery) |
| Total current range |
0A to customizable maximum |
| Current accuracy |
±0.5% F.S (1%-100% range) |
| Voltage sampling |
20 points per channel, 0V-5V range, ±0.5% accuracy |
| Communication |
RS485 to PC, USB/serial connection, supports 200 channels per PC |
Front view of the discharge testing machine
Detailed view of battery connection interface
Operation panel and control interface