Specifications
Brand Name :
LONROY
Voltage :
220 V
Protection Class :
Ip56
Type :
Testing Machine
Overall Dimensions (L*W*H) :
500(L) * 490(W) * 530(H) mm
Place of Origin :
Guangdong, China
customized support :
OEM, ODM, OBM
Application :
Auto Testing
MOQ :
1
Accuracy :
/
power :
---
Accuracy Class :
High Accuracy
Weight :
50 kg
warranty :
1 Year
Description

ASTM D5453 ASTM D4629 Ultraviolet Fluorescence Sulfur Nitrogen Analyzer ASTM D5762 Luminometric Nitrogen N2 Gas Purity Tester

Main Features

1,High sensitivity:LR-ST6000 ultraviolet fluorescence sulfur determination

instrument uses ultraviolet fluorescence method to determine the total

sulfur content, which enhances anti-impurity interference capability,

avoids the complicated operations of the coulometric method on the titration

cell and the resulting instability factors, and greatly improves the

sensitivity of the instrument. The key components of the system are

imported devices, and the detector is designed to be light-tight and airtight,

which ensures the performance of the whole machine reliably.

2,System configuration:

Standard configuration:computer+LR-ST6000 system+Liquid sampler

Other options: solid sampler, gas sampler and mass flowmeter

3,Easy to operate:

The English operating interface based on Windows (11,10,7, XP, Me, 98)

makes the operation more convenient and efficient. Users only need to

click the mouse to complete all parameter settings and condition selection,

and the computer controls the data collection, processing, storage and

printing

——Analytical instrument series products

1. The performance of the instrument is continuously improved, with

beautiful appearance and reasonable structure.

2. The instrument has automatic alarm function for abnormal gas pressure.

3. Digital tracking and display of gas flow and pressure throughout the

process.

4. The computer controls the sampler to perform automatic sample injection

without manual operation.

5. Personalized operation interface and printing format can be designed

according to user requirements.

6. The computer controls the whole process of analysis and data processing,

and displays the working state of the whole process.

7. The unique fluorescent chamber is designed with automatic compensation

function of ultraviolet light source intensity, high sensitivity and low

baseline noise.

8. The aromatic hydrocarbon barrier filtration system and detection system,

equipped with a selective permeation membrane, are protected from

contamination.

9. The special quartz cracking tube requires no disassembly or replacement,

which completely overcomes the drawback of easy carbon deposition in

combustion tubes.

10. The instrument has a gas filtration and purification system.

11. The key components are imported, which reduces the instrument noise and

improves the detection sensitivity.

Membrane dryer Import

Ultraviolet lamp Import

Photomultiplier tube Import

214 nm filter Import

4,The executive standard of the instrument is:

Standard Number

English Name

GB/T 17674 - 2012

Determination of Nitrogen Content in Crude Oil and Its Products by Chemiluminescence

SH/T 0657 - 2007

Determination of Trace Nitrogen in Liquid Petroleum Hydrocarbons by Oxidation Combustion and Chemiluminescence

SH/T 1821

Determination of Nitrogen in Industrial Aromatics by Chemiluminescence

SH/T 0704 - 2001

Determination of Nitrogen Content in Petroleum and Petroleum Products by Oxidative Combustion and Chemiluminescence (Standard for the Petroleum and Petrochemical Industry)

ASTM D4629 - 2017

Standard Test Method for Determining Nitrogen in Liquid Hydrocarbons by Oxidative Combustion and Chemiluminescence

ASTM D5762 - 2012

Test Method for Determining Nitrogen in Petroleum and Petroleum Products by Oxidative Combustion and Chemiluminescence

ASTM D5453 ASTM D4629 Ultraviolet Fluorescence Sulfur Nitrogen Analyzer ASTM D5762 Luminometric Nitrogen N2 Gas Purity Tester

Technical Specification

Basic Parameters

Details

Sample Types

Liquid, Solid, and Gas

Measurement Method

Chemiluminescence (N)

Sample Intake

Solid: 1-20mg; Liquid: 5-20μL; Gas: 1-5mL

Measurement Range

0.01 to 20000 mg/L (Concentration can be diluted for high levels)

Measurement Time

Approximately 2 minutes

Measurement Precision

Concentration (ppm)

RSD (%)

< 1

10

1 ~ 10

8

10~ 100

5

> 100

3

Temperature Control Range

Room temperature to 1300°C

Temperature Accuracy

±1°C

Gas Source Requirements

High purity hydrogen: purity above 99.9%, high purity oxygen: purity above 99.9%

Power Supply

AC 220V ± 22V, 50Hz ± 0.5Hz, 1500 W

Dimensions

500(L) × 490(W) × 530(H) mm

Weight

50 kg

Temperature Control Range

Room temperature to 1300°C

ASTM D5453 ASTM D4629 Ultraviolet Fluorescence Sulfur Nitrogen Analyzer ASTM D5762 Luminometric Nitrogen N2 Gas Purity TesterASTM D5453 ASTM D4629 Ultraviolet Fluorescence Sulfur Nitrogen Analyzer ASTM D5762 Luminometric Nitrogen N2 Gas Purity TesterASTM D5453 ASTM D4629 Ultraviolet Fluorescence Sulfur Nitrogen Analyzer ASTM D5762 Luminometric Nitrogen N2 Gas Purity TesterASTM D5453 ASTM D4629 Ultraviolet Fluorescence Sulfur Nitrogen Analyzer ASTM D5762 Luminometric Nitrogen N2 Gas Purity Tester

Send your message to this supplier
Send Now

ASTM D5453 ASTM D4629 Ultraviolet Fluorescence Sulfur Nitrogen Analyzer ASTM D5762 Luminometric Nitrogen N2 Gas Purity Tester

Ask Latest Price
Brand Name :
LONROY
Voltage :
220 V
Protection Class :
Ip56
Type :
Testing Machine
Overall Dimensions (L*W*H) :
500(L) * 490(W) * 530(H) mm
Place of Origin :
Guangdong, China
Contact Supplier
ASTM D5453 ASTM D4629 Ultraviolet Fluorescence Sulfur Nitrogen Analyzer ASTM D5762 Luminometric Nitrogen N2 Gas Purity Tester
ASTM D5453 ASTM D4629 Ultraviolet Fluorescence Sulfur Nitrogen Analyzer ASTM D5762 Luminometric Nitrogen N2 Gas Purity Tester
ASTM D5453 ASTM D4629 Ultraviolet Fluorescence Sulfur Nitrogen Analyzer ASTM D5762 Luminometric Nitrogen N2 Gas Purity Tester
ASTM D5453 ASTM D4629 Ultraviolet Fluorescence Sulfur Nitrogen Analyzer ASTM D5762 Luminometric Nitrogen N2 Gas Purity Tester
ASTM D5453 ASTM D4629 Ultraviolet Fluorescence Sulfur Nitrogen Analyzer ASTM D5762 Luminometric Nitrogen N2 Gas Purity Tester
ASTM D5453 ASTM D4629 Ultraviolet Fluorescence Sulfur Nitrogen Analyzer ASTM D5762 Luminometric Nitrogen N2 Gas Purity Tester

DONGGUAN LONROY EQUIPMENT CO LTD

Verified Supplier
2 Years
guangdong, dongguan
Since 2008
Business Type :
Manufacturer, Agent, Exporter, Seller
Total Annual :
$5 million -$8 million
Employee Number :
80~200
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement