Item | Specification |
Withstand Voltage Test | Test Voltage: 0–3000V (Customizable To 5000V); Leakage Current: 0–20mA (Customizable To 100mA Or 200mA); Accuracy: ±(3% Of Setting + 5 Digits) |
Insulation Resistance | Test Voltage: DC 500V, 1000V; Test Range: 0–500MΩ; Accuracy: ±(3% Of Setting + 3V) |
Inter-turn Insulation | Peak Voltage: 0–3000V (Customizable To 5000V) |
DC Resistance | Test Range: 0–20kΩ; Accuracy: 0.5% |
Locked-rotor Current (Power) | Test Voltage: 0–300–500V; Current: 0–5–40A; Accuracy: 0.5% |
No-load Current (Power) | Test Voltage: 0–300–500V; Current: 0–5–40A; Accuracy: 0.5% |