Helium Hydrogen Mass Spectrometer Leak Detector- High Sensitivity, Fast Response, Automatic Mobile Leak Detector For Industrial Use [KSNH-400]
1. Product Application and General Requirements
The KSNH-400 series leak detector is a fully automatic mobile helium mass spectrometer leak detector with a silent wheel design, suitable for use in many demanding industries. It adopts the principles of helium mass spectrometry and reverse diffusion, utilizes a 180° non-uniform magnetic field and fully automatic control technology, and realizes automatic helium peak scanning, automatic calibration and automatic range switching. It features short startup time, fast calculation speed, high detection sensitivity and strong anti-interference ability.
2. Performance Characteristics
- Unique gas path design to prevent dust from entering the interior of the instrument.
- Multi-mode function input and output for easy connection to various automation equipment.
- Double iridium ribbon ion source with strong oxidation resistance and long service life.
- Effective separation of machinery and circuits to avoid mutual interference from temperature, electromagnetic fields, etc., making the leak detector operate more stably and reliably.
3. Product Requirements and Main Specifications (Table)
| Minimum detectable leak rate (Vacuum mode) |
3×10⁻¹³ Pa·m³/s |
| Leak rate display range (Vacuum mode) |
1×10⁻² Pa·m³/s ~ 1×10⁻¹³ Pa·m³/s |
| Startup time |
≤ 120 S |
| Response time |
< 0.3 S |
| Maximum pressure at leak detection port |
2000 Pa |
| Rough detection vacuum degree at leak detection port |
2000 ~ 200 Pa |
| Medium detection vacuum degree at leak detection port |
200 ~ 40 Pa |
| Fine detection vacuum degree at leak detection port |
Below 40 Pa |
| Helium pumping speed of the leak detector |
5 L/s |
| Display units |
Pa·m³/s, mbar·l/s, atm·cc/s |
| Display interfaces |
Curve graph, histogram, numerical display |
| Leak detector dimensions |
870×523×1166 (unit not specified, generally mm) |
| Control mode |
One-key fully automatic control; automatic zero adjustment; automatic calibration; automatic/manual switching of double filaments |
| Display mode |
LCD touch screen display (rotatable by 270°); configurable with 4 groups of alarm values |
| Core components and technology |
German imported turbo high-vacuum molecular pump; German BURKERT solenoid valve; imported AD chip; mechanical pump (Baosi); new mass spectrometry technology with 180° ionization deflection; equipped with standard leak hole and calibration certificate |
4. Operating Environment
- This product is for indoor, industrial, and laboratory use only.
- Temperature: 5℃ ~ 40℃; Relative humidity: ≤ 80%.
- Operating voltage: Single-phase 220V ± 10%, 50Hz.
- Maximum operating current: 10A.