The Schneider Electric SXWHIO8CABLE10001 is the dedicated wiring harness cable accessory for the SXWHIO8DIDO10001 Multi I/O Module (CRS-HIO-DIDO-8) in the SpaceLogic Connected Room Solution (CRS-H). It provides the pre-fabricated, connector-matched cable assembly that links the SXWHIO8DIDO10001 module to field wiring terminals in hotel room panel boards — eliminating the need for manual wire termination at the I/O module and significantly reducing installation time and wiring error risk.
Technical Specifications
| Part Number |
SXWHIO8CABLE10001 |
| Product Type |
Wiring Harness / Pre-fabricated Cable Accessory |
| Compatible Module |
SXWHIO8DIDO10001 (CRS-HIO-DIDO-8 Multi I/O Module) |
| Series |
SpaceLogic Connected Room Solution (CRS-H) |
| Connector Type |
Pre-fitted connectors matched to SXWHIO8DIDO10001 terminal layout |
| Channel Coverage |
8 digital input channels + 8 indicator output channels |
| Conductor Labeling |
Yes — individual channels labeled for identification |
| Installation |
Plug-and-connect (no wire termination at module required) |
| Application |
Hotel room panel board wiring for CRS-H I/O module installations |
| Certifications |
CE, RoHS Compliant |
| Compatible Controllers |
SXWRCF16B10001, SXWRCF16B10002 (via SXWHIO8DIDO10001) |
| Always Ordered With |
SXWHIO8DIDO10001 (sold separately) |
Key Features & Benefits
- Pre-fabricated cable assembly with matched connectors
- Eliminates manual wire termination at I/O module
- Labeled conductors for all 16 channels (8 DI + 8 DO)
- Reduces installation time and wiring error risk
- Plug-and-connect installation method
Applications & Project Benefits
The SXWHIO8CABLE10001 is a mandatory companion purchase with every SXWHIO8DIDO10001 module in hotel room CRS-H installations. In large hotel projects deploying hundreds of guest rooms, the pre-fabricated cable harness provides significant labor savings.
Time Savings: Connecting the 16-channel I/O module via pre-fitted connector takes approximately 2–3 minutes per room versus 15–20 minutes for manual wire termination — a saving of over 200 man-hours on a 200-room hotel project.
The labeled conductors reduce the risk of cross-wiring the DND and MUR indicator outputs (a common commissioning error that results in reversed room status signals visible to housekeeping staff). Procurement teams consistently order the SXWHIO8CABLE10001 and SXWHIO8DIDO10001 in identical quantities on hotel project bill-of-materials.
Note: This cable is sold separately and must be ordered with the compatible SXWHIO8DIDO10001 Multi I/O Module.